Alcohol Biosensing by Polyamidoamine (PAMAM)/Cysteamine/Alcohol Oxidase-Modified Gold Electrode

被引:46
作者
Akin, Mehriban [1 ]
Yuksel, Merve [1 ]
Geyik, Caner [1 ]
Odaci, Dilek [1 ]
Bluma, Arne [2 ]
Hoepfner, Tim [2 ]
Beutel, Sascha [2 ]
Scheper, Thomas [2 ]
Timur, Suna [1 ]
机构
[1] Ege Univ, Fac Sci, Dept Biochem, TR-35100 Bornova, Turkey
[2] Leibniz Univ Hannover, Inst Tech Chem, D-30167 Hannover, Germany
关键词
alcohol oxidase; electrochemical enzyme biosensor; dendrimer; self-assembled monolayers; AMPEROMETRIC BIOSENSOR; STARBURST DENDRIMERS; ENZYME ELECTRODE; GAS-CHROMATOGRAPHY; MELDOLAS BLUE; ETHANOL; IMMOBILIZATION; DEHYDROGENASE; STABILIZATION; SENSOR;
D O I
10.1002/btpr.372
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
A highly stable and sensitive amperometric alcohol biosensor was developed by immobilizing alcohol oxidase (A OX) through Polyamidoamine (PAMAM) dendrimers on a cysteamine-modified gold electrode surface. Ethanol determination is based on the consumption of dissolved oxygen content due to the enzymatic reaction. The decrease in oxygen level was monitored at -0.7 V vs. Ag/AgCl and correlated with ethanol concentration. Optimization of variables affecting the system was performed. The optimized ethanol biosensor showed a wide linearity from 0.025 to 1.0 mM with 100 s response time and detection limit of (LOD) 0.016 mM. In the characterization studies, besides linearity some parameters such as operational and storage stability, reproducibility, repeatability, and substrate specificity were studied in detail. Stability studies showed a good preservation of the bioanalytical properties of the sensor, 67% of its initial sensitivity was kept after 1 month storage at 4 degrees C. The analytical characteristics of the system were also evaluated for alcohol determination in flow injection analysis (FIA) mode. Finally, proposed biosensor was applied for ethanol analysis in various alcoholic beverage as well as offline monitoring of alcohol production through the yeast cultivation. (C) 2010 American Institute of Chemical Engineers Biotechnol. Prog., 26: 896-906, 2010
引用
收藏
页码:896 / 906
页数:11
相关论文
共 78 条
[1]   An amperometric microbial biosensor development based on Candida tropicalis yeast cells for sensitive determination of ethanol [J].
Akyilmaz, E ;
Dinçkaya, E .
BIOSENSORS & BIOELECTRONICS, 2005, 20 (07) :1263-1269
[2]  
[Anonymous], ELECTROANALYTICAL CH
[3]   Operation and performance of analytical packed-bed reactors with an immobilised alcohol oxidase [J].
Azevedo, AM ;
Cabral, JMS ;
Gibson, TD ;
Fonseca, LP .
JOURNAL OF MOLECULAR CATALYSIS B-ENZYMATIC, 2004, 28 (2-3) :45-53
[4]   Thermal and operational stabilities of Hansenula polymorpha alcohol oxidase [J].
Azevedo, AM ;
Cabral, JMS ;
Prazeres, DMF ;
Gibson, TD ;
Fonseca, LP .
JOURNAL OF MOLECULAR CATALYSIS B-ENZYMATIC, 2004, 27 (01) :37-45
[5]   Oxidase enzyme immobilisation through electropolymerised films to assemble biosensors for batch and flow injection analysis [J].
Badea, M ;
Curulli, A ;
Palleschi, G .
BIOSENSORS & BIOELECTRONICS, 2003, 18 (5-6) :689-698
[6]   An alcohol oxidase biosensor using PNR redox mediator at carbon film electrodes [J].
Barsan, Madalina M. ;
Brett, Christopher M. A. .
TALANTA, 2008, 74 (05) :1505-1510
[7]   AN ENZYME ELECTRODE FOR ONLINE DETERMINATION OF ETHANOL AND METHANOL [J].
BELGHITH, H ;
ROMETTE, JL ;
THOMAS, D .
BIOTECHNOLOGY AND BIOENGINEERING, 1987, 30 (09) :1001-1005
[8]   Preparation of a stable biocatalyst of bovine liver catalase using immobilization and postimmobilization techniques [J].
Betancor, L ;
Hidalgo, A ;
Fernández-Lorente, G ;
Mateo, C ;
Fernández-Lafuente, R ;
Guisan, JM .
BIOTECHNOLOGY PROGRESS, 2003, 19 (03) :763-767
[9]   Development of a disposable ethanol biosensor based on a chemically modified screen-printed electrode coated with alcohol oxidase for the analysis of beer [J].
Boujtita, M ;
Hart, JP ;
Pittson, R .
BIOSENSORS & BIOELECTRONICS, 2000, 15 (5-6) :257-263
[10]   Biosensors for analysis of ethanol in food: Effect of the pasting liquid [J].
Boujtita, M ;
Chapleau, M ;
ElMurr, N .
ANALYTICA CHIMICA ACTA, 1996, 319 (1-2) :91-96