ECG-gated chest CT angiography with 64-MDCT and tri-phasic IV contrast administration regimen in patients with acute non-specific chest pain

被引:59
作者
Litmanovitch, Diana [1 ,2 ,3 ]
Zamboni, Giulia A. [1 ,2 ,3 ]
Hauser, Thomas H. [2 ,3 ,4 ]
Lin, Pei-Jan P. [1 ,2 ,3 ]
Clouse, Melvin E. [1 ,2 ,3 ]
Raptopoulos, Vassilios [1 ,2 ,3 ]
机构
[1] Beth Israel Deaconess Med Ctr, Dept Radiol, Boston, MA 02215 USA
[2] Harvard Univ, Sch Med, Boston, MA 02215 USA
[3] Harvard Univ, Sch Med, Dept Radiol, Boston, MA 02115 USA
[4] Beth Israel Deaconess Med Ctr, Dept Cardiol, Boston, MA 02215 USA
关键词
computed tomography; coronary arteries; ECG-gated chest CT; acute chest pain; emergency department; DUAL-SOURCE CT; THIN-SECTION CT; CORONARY-ANGIOGRAPHY; COMPUTED-TOMOGRAPHY; IMAGE QUALITY; HELICAL CT; FEASIBILITY; REDUCTION; DIAGNOSIS; HEART;
D O I
10.1007/s00330-007-0739-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to evaluate chest CTA protocol using retrospective ECG-gating and triphasic IV contrast regimen for comprehensive evaluation of patients with acute non-specific chest pain. ECG-triggered dose modulation was used with a 64-MDCT scanner in 56 non-critically ill patients with acute nonspecific chest pain using triphasic IV regimen: 50 ml contrast followed by 50 ml 60% contrast/saline and 30 ml normal saline. Lungs, aorta, pulmonary and coronary arteries were graded on a 5-point scale (5, best). Aorta and pulmonary artery attenuation was measured and three coronary artery groups were evaluated. Comparison with invasive coronary angiography was obtained in nine patients on a per segment (16 total) basis. Dosimetry values were obtained. Studies were satisfactory in all patients (score > 3). Aorta and pulmonary artery attenuation was > 200 HU in 90.5%. Lung or pleura, non-cardiac vascular and coronary arteries disease were detected in 20, 11 and 16 patients, respectively. Median coronary angiography (grade 5) was significantly higher than acceptable for diagnosis grade 4 (p < 0.001). Per segment, weighted kappa statistic was 0.79 indicating substantial agreement with catheter angiography (p < 0.001). Average DLP was 1,490 +/- 412 mGy-cm. Gated 64-MDCT angiography with triphasic IV contrast is a robust multipurpose technique for patients with acute non-specific chest pain.
引用
收藏
页码:308 / 317
页数:10
相关论文
共 23 条
[11]   ECG-gated 64-MDCT angiography in the differential diagnosis of acute chest pain [J].
Johnson, Thorsten R. C. ;
Nikolaou, Konstantin ;
Wintersperger, Bernd J. ;
Knez, Andreas ;
Boekstegers, Peter ;
Reiser, Maximilian F. ;
Becker, Christoph R. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (01) :76-82
[12]   Dual-source CT cardiac imaging: initial experience [J].
Johnson, Thorsten R. C. ;
Nikolaou, Konstantin ;
Wintersperger, Bernd J. ;
Leber, Alexander W. ;
von Ziegler, Franz ;
Rist, Carsten ;
Buhmann, Sonja ;
Knez, Andreas ;
Reiser, Maximilian F. ;
Becker, Christoph R. .
EUROPEAN RADIOLOGY, 2006, 16 (07) :1409-1415
[13]   Quantification of obstructive and nonobstructive coronary lesions by 64-slice computed tomography - A comparative study with quantitative coronary angiography and intravascular ultrasound [J].
Leber, AW ;
Knez, A ;
von Ziegler, F ;
Becker, A ;
Nikolaou, K ;
Paul, S ;
Wintersperger, B ;
Reiser, M ;
Becker, CR ;
Steinbeck, G ;
Boekstegers, P .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 46 (01) :147-154
[14]   ECG-gated multislice spiral CT for diagnosis of acute pulmonary embolism [J].
Marten, K ;
Engelke, C ;
Funke, M ;
Obenauer, S ;
Baum, F ;
Grabbe, E .
CLINICAL RADIOLOGY, 2003, 58 (11) :862-868
[15]   Radiation dose in computed tomography of the heart [J].
Morin, RL ;
Gerber, TC ;
McCollough, CH .
CIRCULATION, 2003, 107 (06) :917-922
[16]   MDCT angiography of acute chest pain: Evaluation of ECG-gated and nongated techniques [J].
Raptopoulos, Vassilios D. ;
Boiselle, Phillip B. ;
Michailidis, Nikolaos ;
Handwerker, Jason ;
Sabir, Adeel ;
Edlow, Jonathan A. ;
Pedrosa, Ivan ;
Kruskal, Jonathan B. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 186 (06) :S346-S356
[17]   Thoracic aorta: Motion artifact reduction with retrospective and prospective electrocardiography-assisted multi-detector row CT [J].
Roos, JE ;
Willmann, JK ;
Weishaupt, D ;
Lachat, M ;
Marincek, B ;
Hilfiker, PR .
RADIOLOGY, 2002, 222 (01) :271-277
[18]   Accuracy of dual-source CT coronary angiography: first experience in a high pre-test probability population without heart rate control [J].
Scheffel, Hans ;
Alkadhi, Hatem ;
Plass, Andre ;
Vachenauer, Robert ;
Desbiolles, Lotus ;
Gaemperli, Oliver ;
Schepis, Tiziano ;
Frauenfelder, Thomas ;
Schertler, Thomas ;
Husmann, Lars ;
Grunenfelder, Juerg ;
Genoni, Michele ;
Kaufmann, Philipp A. ;
Marincek, Borut ;
Leschka, Sebastian .
EUROPEAN RADIOLOGY, 2006, 16 (12) :2739-2747
[19]   Electrocardiographically gated thin-section CT of the lung [J].
Schoepf, UJ ;
Becker, CR ;
Bruening, RD ;
Helmberger, T ;
Staebler, A ;
Leimeister, P ;
Reiser, MF .
RADIOLOGY, 1999, 212 (03) :649-654
[20]   Bias in research studies [J].
Sica, GT .
RADIOLOGY, 2006, 238 (03) :780-789