MR-IMAGING OF THE MUSCULOSKELETAL SYSTEM - TECHNICAL CONSIDERATIONS FOR ENHANCING IMAGE QUALITY AND DIAGNOSTIC YIELD

被引:29
作者
RUBIN, DA
KNEELAND, JB
机构
[1] Department of Radiology, Montefiore University Hospital, UPMC, Pittsburgh, PA 15213
关键词
D O I
10.2214/ajr.163.5.7976893
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
MR imaging has revolutionized the diagnostic evaluation of musculoskeletal disorders, becoming the study of choice for many indications. Without the use of ionizing radiation, MR imaging can safely produce high contrast, high-resolution cross-sectional images of the body in virtually any imaging plane. To maximize the diagnostic information of musculoskeletal MR studies, the radiologist must consistently produce the highest quality images possible, which in turn depends on a complex interaction among multiple technical factors. We present our perspectives on some of these factors, stressing the impact each has for specific indications. The material presented herein should be viewed as guidelines for improving image quality and diagnostic yield. However, individual systems and applications vary considerably, and the radiologist must ''fine-tune'' protocols to reflect the available resources, patient population, and preferences of the referring clinicians.
引用
收藏
页码:1155 / 1163
页数:9
相关论文
共 53 条
[21]
PARALLEL IMAGE ACQUISITION FROM NONINTERACTING LOCAL COILS [J].
HYDE, JS ;
JESMANOWICZ, A ;
FRONCISZ, W ;
KNEELAND, JB ;
GRIST, TM ;
CAMPAGNA, NF .
JOURNAL OF MAGNETIC RESONANCE, 1986, 70 (03) :512-517
[22]
MEASURING SIGNAL-TO-NOISE RATIOS IN MR IMAGING [J].
KAUFMAN, L ;
KRAMER, DM ;
CROOKS, LE ;
ORTENDAHL, DA .
RADIOLOGY, 1989, 173 (01) :265-267
[23]
MULTISECTION FAT-WATER IMAGING WITH CHEMICAL-SHIFT SELECTIVE PRESATURATION [J].
KELLER, PJ ;
HUNTER, WW ;
SCHMALBROCK, P .
RADIOLOGY, 1987, 164 (02) :539-541
[24]
REFORMATTED 3-DIMENSIONAL FOURIER-TRANSFORM GRADIENT-RECALLED ECHO MR-IMAGING OF THE ANKLE - SPECTRUM OF NORMAL AND ABNORMAL FINDINGS [J].
KLEIN, MA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 161 (04) :831-836
[25]
KNEELAND JB, 1989, RADIOLOGY, V171, P1
[26]
Listerud J, 1992, Magn Reson Q, V8, P199
[27]
COMPARING THE FAISE METHOD WITH CONVENTIONAL DUAL-ECHO SEQUENCES [J].
MELKI, PS ;
MULKERN, RV ;
PANYCH, LP ;
JOLESZ, FA .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1991, 1 (03) :319-326
[28]
MR-IMAGING OF BONE-MARROW LESIONS - RELATIVE CONSPICUOUSNESS ON T1-WEIGHTED, FAT-SUPPRESSED T2-WEIGHTED, AND STIR IMAGES [J].
MIROWITZ, SA ;
APICELLA, P ;
REINUS, WR ;
HAMMERMAN, AM .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 162 (01) :215-221
[29]
SAMPLING BANDWIDTH AND FAT SUPPRESSION - EFFECTS ON LONG TR/TE MR IMAGING OF THE ABDOMEN AND PELVIS AT 1.5-T [J].
MITCHELL, DG ;
VINITSKI, S ;
RIFKIN, MD ;
BURK, DL .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 153 (02) :419-425
[30]
ROTATOR CUFF - EVALUATION WITH FAT-SUPPRESSED MR ARTHROGRAPHY [J].
PALMER, WE ;
BROWN, JH ;
ROSENTHAL, DI .
RADIOLOGY, 1993, 188 (03) :683-687