BLINDED COMPARISON OF BIOPSY NEEDLES AND AUTOMATED DEVICES IN-VITRO .2. BIOPSY OF MEDICAL RENAL-DISEASE

被引:35
作者
HOPPER, KD [1 ]
ABENDROTH, CS [1 ]
STURTZ, KW [1 ]
MATTHEWS, YL [1 ]
SHIRK, SJ [1 ]
STEVENS, LA [1 ]
机构
[1] PENN STATE UNIV,MILTON S HERSHEY MED CTR,DEPT PATHOL,HERSHEY,PA 17033
关键词
D O I
10.2214/ajr.161.6.8249746
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to compare several of the commonly used manual biopsy needles with several of the new automated biopsy devices (biopsy guns) for biopsy of medical renal disease. MATERIALS AND METHODS. Ten different biopsy needles or automated devices were each used to do two biopsies of 10 cadaveric kidneys. The specimens were reviewed in a blinded fashion by a pathologist using a previously published histopathologic scale. RESULTS. Of the four conventional biopsy needles tested (16-gauge Jamshidi, 18-gauge Sure-Cut, 14-gauge Tru-Cut, and 14-gauge Vim Silverman), the Jamshidi needle obtained the greatest average number of glomeruli (5.64). Results similar to those obtained with the conventional needles were obtained with the 16- and 18-gauge Biopty and Ultra-Cut biopsy guns. The 18-gauge Autovac gun with either a 2- or 4-cm depth of biopsy suffered from a significant number of biopsies from which no tissue was obtained. The 14-gauge Biopty gun was clearly superior, leading in all graded categories including the average number of glomeruli (8.11) per biopsy. CONCLUSION. The automated biopsy device, or biopsy gun, can provide more diagnostic specimens than can manual or conventional needles in biopsy for medical renal disease.
引用
收藏
页码:1299 / 1301
页数:3
相关论文
共 24 条
  • [1] ALTERBARMAKIAN VK, 1981, UROLOGY, V28, P118
  • [2] MINICORE NEEDLE-BIOPSY OF KIDNEY-TRANSPLANTS - A SAFER SAMPLING METHOD
    BELITSKY, P
    GUPTA, R
    [J]. JOURNAL OF UROLOGY, 1990, 144 (02) : 310 - 311
  • [3] NEEDLE-BIOPSY OF RENAL-ALLOGRAFTS - COMPARISON OF 2 TECHNIQUES
    BOGAN, ML
    KOPECKY, KK
    KRAFT, JL
    HOLLADAY, AO
    FILO, RS
    LEAPMAN, SB
    THOMALLA, JV
    [J]. RADIOLOGY, 1990, 174 (01) : 273 - 275
  • [4] NON-HEMORRHAGIC DECREMENTS IN HEMATOCRIT VALUES AFTER PERCUTANEOUS RENAL BIOPSY
    BOLTON, WK
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1977, 238 (12): : 1266 - 1268
  • [5] Diaz-Buxo J A, 1975, Clin Nephrol, V4, P223
  • [6] ULTRASOUND GUIDED PERCUTANEOUS RENAL BIOPSY USING AN AUTOMATIC CORE BIOPSY SYSTEM
    DOWD, PE
    MATA, JA
    CROW, A
    CULKIN, DJ
    VENABLE, DD
    [J]. JOURNAL OF UROLOGY, 1991, 146 (05) : 1216 - 1217
  • [7] ARTERIOVENOUS FISTULAE SECONDARY TO RENAL BIOPSY - AN EXPERIMENTAL STUDY IN RABBIT
    EKELUND, L
    [J]. ACTA RADIOLOGICA-DIAGNOSIS, 1970, 10 (03): : 218 - +
  • [8] RENAL BIOPSY - CURRENT VIEWS AND CONTROVERSIES
    GAULT, MH
    MUEHRCKE, RC
    [J]. NEPHRON, 1983, 34 (01) : 1 - 34
  • [9] AUTOMATED BIOPSY DEVICES - A BLINDED EVALUATION
    HOPPER, KD
    ABENDROTH, CS
    STURTZ, KW
    MATTHEWS, YL
    STEVENS, LA
    SHIRK, SJ
    [J]. RADIOLOGY, 1993, 187 (03) : 653 - 660
  • [10] BLINDED COMPARISON OF BIOPSY NEEDLES AND AUTOMATED DEVICES IN-VITRO .1. BIOPSY OF DIFFUSE HEPATIC-DISEASE
    HOPPER, KD
    ABENDROTH, CS
    STURTZ, KW
    MATTHEWS, YL
    SHIRK, SJ
    STEVENS, LA
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 161 (06) : 1293 - 1297