DEVELOPMENT OF A NEEDLE TYPE GLUCOSE BIOSENSOR

被引:4
作者
ABDELHAMID, I
ATANASOV, P
WILKINS, E
机构
[1] Department of Chemical and Nuclear Engineering, University of New Mexico, Albuquerque, NM
关键词
GLUCOSE BIOSENSOR; NEEDLE SENSOR; GLUCOSE CONCENTRATION MONITORING;
D O I
10.1080/00032719408006382
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A needle type glucose biosensor has been developed for monitoring of glucose levels during hemorrhagic shock. The sensor employs polycarbonate membranes that are either untreated or treated with Nafion or Silastic, and Glucose Oxidase enzyme which is immobilized on modified carbon powder in a gel matrix. Sensor performance was evaluated in vitro and the sensor showed a sensitivity of up to 10 nA/mM and a linear range of up to 30 mM. Evaluation of the sensor response in serum showed similar sensitivity and linear range as obtained using calibration curves in buffer solution. The sensors were operated continuously for 28 days in phosphate buffer solution and no significant change in the sensitivity and the linear range was observed during the first 7 days. Sensors show a minimum change in their performance when stored inactive in buffer at 4 degrees C for at least eight weeks.
引用
收藏
页码:1453 / 1473
页数:21
相关论文
共 26 条
[1]   CHARACTERIZATION OF MIXED ENZYME-MEDIATOR-CARBON PASTE ELECTRODES [J].
AMINE, A ;
KAUFFMANN, JM ;
GUILBAULT, GG ;
BACHA, S .
ANALYTICAL LETTERS, 1993, 26 (07) :1281-1299
[2]   GLUCOSE BIOSENSOR BASED ON OXYGEN-ELECTRODE .1. SILASTIC COATED POLYCARBONATE MEMBRANES FOR BIOSENSOR APPLICATION [J].
ATANASOV, P ;
WILKINS, E .
ANALYTICAL LETTERS, 1993, 26 (08) :1587-1612
[3]   DESIGN AND INVITRO STUDIES OF A NEEDLE-TYPE GLUCOSE SENSOR FOR SUBCUTANEOUS MONITORING [J].
BINDRA, DS ;
ZHANG, YN ;
WILSON, GS ;
STERNBERG, R ;
THEVENOT, DR ;
MOATTI, D ;
REACH, G .
ANALYTICAL CHEMISTRY, 1991, 63 (17) :1692-1696
[4]   INVIVO MEASUREMENT OF SUBCUTANEOUS GLUCOSE-CONCENTRATIONS WITH AN ENZYMATIC GLUCOSE SENSOR AND A WICK METHOD [J].
BRUCKEL, J ;
KERNER, W ;
ZIER, H ;
STEINBACH, G ;
PFEIFFER, EF .
KLINISCHE WOCHENSCHRIFT, 1989, 67 (09) :491-495
[5]   AMPEROMETRIC NEEDLE-TYPE GLUCOSE SENSOR BASED ON A MODIFIED PLATINUM-ELECTRODE WITH DIMINISHED RESPONSE TO INTERFERING MATERIALS [J].
CHEN, CY ;
GOTOH, M ;
MAKINO, H ;
SU, YC ;
TAMIYA, E ;
KARUBE, I .
ANALYTICA CHIMICA ACTA, 1992, 265 (01) :5-14
[6]  
Churchouse S.J., 1986, ANAL P, V23, P146
[7]  
FIEDMAN SG, 1982, J TRAUMA, V22, P86
[8]   MINIATURE GLUCOSE BIOSENSOR WITH EXTENDED LINEARITY [J].
KANAPIENIENE, JJ ;
DEDINAITE, AA ;
LAURINAVICIUS, VSA .
SENSORS AND ACTUATORS B-CHEMICAL, 1992, 10 (01) :37-40
[9]  
KERNER W, 1988, HORM METAB RES, V20, P8
[10]  
KONDO T, 1981, T AM SOC ART INT ORG, V27, P250