PERCUTANEOUS NATIVE RENAL BIOPSY - COMPARISON OF A 1.2-MM SPRING-DRIVEN SYSTEM WITH A TRADITIONAL 2-MM HAND-DRIVEN SYSTEM

被引:68
作者
DOYLE, AJ
GREGORY, MC
TERREROS, DA
机构
[1] UNIV UTAH,HLTH SCI CTR,DEPT RADIOL,DIV NEPHROL,SALT LAKE CITY,UT 84132
[2] UNIV UTAH,HLTH SCI CTR,DEPT SURG PATHOL,DIV GEN INTERNAL MED,SALT LAKE CITY,UT 84132
[3] UNIV UTAH,HLTH SCI CTR,DEPT SURG PATHOL,DIV NEPHROL,SALT LAKE CITY,UT 84132
[4] UNIV UTAH,HLTH SCI CTR,DEPT MED,DIV GEN INTERNAL MED,SALT LAKE CITY,UT 84132
[5] UNIV UTAH,HLTH SCI CTR,DEPT MED,DIV NEPHROL,SALT LAKE CITY,UT 84132
关键词
RENAL BIOPSY; BIOPSY GUN; TRUCUT NEEDLE; MEDITECH NEEDLE; KIDNEY BIOPSY; BIOPSY COMPLICATIONS;
D O I
10.1016/S0272-6386(12)80370-2
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Over the last few years spring-driven mechanical biopsy guns have been introduced for performing renal biopsies. There has been little research done comparing these guns with traditional hand-driven needles in performing biopsies of native kidneys. We wished to compare our experience with the two needle types. We studied retrospectively the results and complication rates of 155 native kidney biopsies. Sixty-nine were performed with hand-driven 14-gauge needles and eighty-six with 18-gauge, spring-driven biopsy guns. Sufficient tissue for diagnosis was obtained in 96% of cases in the hand-driven group compared with 99% in the biopsy gun group (P = NS). Complications occurred in six cases in the hand-driven group compared with one case in the biopsy gun group (P = 0.02). As expected, the reported number of glomeruli per core in the 14-gauge cores was greater than in the 18-gauge cores (16.5 v 6.2, P < 0.01). This was partially offset by the greater number of passes made with the smaller needle. We conclude that similar results can be expected from both biopsy methods, with a possible slight decrease in complications using biopsy guns with smaller needle diameters. © 1994, National Kidney Foundation. All rights reserved. All rights reserved.
引用
收藏
页码:498 / 503
页数:6
相关论文
共 36 条
[31]   RENAL BIOPSY IN DIFFUSE RENAL-DISEASE - EXPERIENCE WITH A 14-GAUGE AUTOMATED BIOPSY GUN [J].
TUNG, KT ;
DOWNES, MO ;
ODONNELL, PJ .
CLINICAL RADIOLOGY, 1992, 46 (02) :111-113
[32]  
TURNER MW, 1986, CLIN NEPHROL, V26, P217
[33]   A NEW TECHNIQUE FOR RENAL-ALLOGRAFT BIOPSY [J].
UBHI, CS ;
IRVING, HC ;
GUILLOU, PJ ;
GILES, GR .
BRITISH JOURNAL OF RADIOLOGY, 1987, 60 (714) :599-600
[34]  
WAHLBERG J, 1988, TRANSPLANT P, V20, P419
[35]  
WICKRE CG, 1982, AM J NEPHROL, V2, P173, DOI 10.1159/000166640
[36]   PERCUTANEOUS RENAL BIOPSY UTILIZING REAL-TIME, ULTRASONIC GUIDANCE AND A SEMIAUTOMATED BIOPSY DEVICE [J].
WISEMAN, DA ;
HAWKINS, R ;
NUMEROW, LM ;
TAUB, KJ .
KIDNEY INTERNATIONAL, 1990, 38 (02) :347-349