EVALUATION OF CDZNTE DETRACTORS FOR SOFT-X-RAY APPLICATIONS

被引:41
作者
NIEMELA, A
SIPILA, H
机构
[1] Outokumpu Instruments Oy, FIN-02201 Espoo, Riihitontuntie 7 C
关键词
D O I
10.1109/23.322857
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
High resistivity CdZnTe is a very promising material for X-ray detection at room temperature or slightly below. Cooling a Cd0.8Zn0.2Te crystal down to -30-degrees-C reduces the leakage current to the picoamp level, which enables the use of low-noise pulsed optical feedback instead of noisier resistive feedback preamplifiers. Also, longer shaping time constants at the linear amplifier can be used for the optimum resolution. We have obtained resolutions of 240 eV (FWHM) for the 5.9-keV Fe-55 line at -40-degrees-C and of 282 eV at -30-degrees-C. The Fano factor for the material at -40-degrees-C was calculated to be 0.14. These results compare well with the results obtained with peltier-cooled HgI2 detectors.
引用
收藏
页码:1054 / 1057
页数:4
相关论文
共 3 条
[1]   CD1-XZNXTE4 GAMMA-RAY DETECTORS [J].
BUTLER, JF ;
LINGREN, CL ;
DOTY, FP .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1992, 39 (04) :605-609
[2]  
BUTLER JF, 1993, 1993 SPIE INT S SAN
[3]   CADMIUM TELLURIDE DETECTORS WITH THERMOELECTRIC COOLING [J].
KHUSAINOV, AK .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 322 (03) :335-340