THE ESTIMATION OF OCCUPATIONAL EFFECTIVE DOSE IN DIAGNOSTIC-RADIOLOGY WITH 2 DOSIMETERS

被引:96
作者
NIKLASON, LT
MARX, MV
CHAN, HP
机构
[1] HARVARD UNIV, SCH MED, DEPT RADIOL, BOSTON, MA 02114 USA
[2] UNIV MICHIGAN HOSP, DEPT RADIOL, ANN ARBOR, MI 48109 USA
来源
HEALTH PHYSICS | 1994年 / 67卷 / 06期
关键词
DOSIMETRY; EXPOSURE; OCCUPATIONAL; RADIATION; IONIZING; RADIATION PROTECTION;
D O I
10.1097/00004032-199412000-00003
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Annual effective dose limits have been proposed by national and international radiation protection committees. Radiation protection agencies must decide upon a method of converting the radiation dose measured from dosimeters to an estimate of effective dose. A proposed method for the estimation of effective dose from the radiation dose to two dosimeters is presented. Correction factors are applied to an over-apron collar dose and an under-apron dose to estimate the effective dose. Correction factors are suggested for two cases, both with and without a thyroid shield. Effective dose may be estimated by the under-apron dose plus 6% of the over-collar dose if a thyroid shield is not worn or plus 2% of the over-collar dose if a thyroid shield is worn. This method provides a reasonable estimate of effective dose that is independent of lead apron thickness and accounts for the use of a thyroid shield.
引用
收藏
页码:611 / 615
页数:5
相关论文
共 17 条
[1]  
[Anonymous], 1991, ICRP PUBL, V60, P1
[2]   THE RELATIONSHIP OF EFFECTIVE DOSE TO PERSONNEL AND MONITOR READING FOR SIMULATED FLUOROSCOPIC IRRADIATION CONDITIONS [J].
FAULKNER, K ;
MARSHALL, NW .
HEALTH PHYSICS, 1993, 64 (05) :502-508
[3]   ESTIMATION OF EFFECTIVE DOSE EQUIVALENT TO STAFF IN DIAGNOSTIC-RADIOLOGY [J].
FAULKNER, K ;
HARRISON, RM .
PHYSICS IN MEDICINE AND BIOLOGY, 1988, 33 (01) :83-91
[4]  
Gill J R, 1980, 5 INT C INT RAD PROT, V1, P15
[5]   CENTRAL-AXIS DEPTH-DOSE DATA FOR DIAGNOSTIC-RADIOLOGY [J].
HARRISON, RM .
PHYSICS IN MEDICINE AND BIOLOGY, 1981, 26 (04) :657-670
[6]   How will the new definition of 'effective dose' modify estimates of dose in diagnostic radiology? [J].
Huda, W. ;
McLellan, J. ;
McLellan, Y. .
Journal of Radiological Protection, 1991, 11 (04)
[7]  
HUDSON CG, 1984, RAD PROTECTION M JAN, P43
[8]   INTERVENTIONAL RADIOLOGISTS - OCCUPATIONAL RADIATION-DOSES AND RISKS [J].
NIKLASON, LT ;
MARX, MV ;
CHAN, HP .
RADIOLOGY, 1993, 187 (03) :729-733
[9]   PERSONNEL DOSIMETER ANGULAR RESPONSE PROPERTIES AND THE ADOPTION OF ICRU REPORT-39 QUANTITIES [J].
PILTINGSRUD, HV ;
ROBERSON, PL .
HEALTH PHYSICS, 1992, 62 (05) :385-394
[10]  
REECE WD, 1985, NUREGCR9279