PREPARATION AND EVALUATION OF POLYACRYLATE-COATED FUSED-SILICA CAPILLARIES FOR REVERSED-PHASE OPEN-TUBULAR LIQUID-CHROMATOGRAPHY

被引:35
作者
SWART, R [1 ]
KRAAK, JC [1 ]
POPPE, H [1 ]
机构
[1] UNIV AMSTERDAM,ANALYT CHEM LAB,1018 WV AMSTERDAM,NETHERLANDS
关键词
D O I
10.1016/0021-9673(94)80277-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
By in situ photopolymerization of acrylates, thick polyacrylate films can be immobilized in 10-mu m fused-silica capillaries. Up to 1.9-mu m thick films can be produced in 0.3-1.2 m long capillaries, resulting in phase ratios >1.0 and leading to columns with high mass loadability. Owing to the high mass loadability, application of ''on-column'' UV detection is possible. The effect of incorporating alkyl acrylates in the film on retention behaviour and efficiency was extensively investigated. The success rate of the preparation of silicone-ethylhexyl acrylate films is almost 100%. The polyacrylate films are stable towards basic solutions up to pH 12. The column efficiency is demonstrated with separations of anthracene derivatives. A fast separation of methyl-substituted benzenes with on-column UV detection is shown.
引用
收藏
页码:25 / 38
页数:14
相关论文
共 15 条
[1]   RAYLEIGH INSTABILITY OF STATIONARY PHASE FILMS IN CAPILLARY COLUMN CHROMATOGRAPHY [J].
BARTLE, KD ;
WOOLLEY, CL ;
MARKIDES, KE ;
LEE, ML ;
HANSEN, RS .
JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1987, 10 (03) :128-136
[2]   ROLE OF THE CHAIN-LENGTH OF CHEMICALLY BONDED PHASES AND THE RETENTION MECHANISM IN REVERSED-PHASE LIQUID-CHROMATOGRAPHY [J].
BERENDSEN, GE ;
DEGALAN, L .
JOURNAL OF CHROMATOGRAPHY, 1980, 196 (01) :21-37
[3]   STANDARDIZATION OF TEST CONDITIONS FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY COLUMNS [J].
BRISTOW, PA ;
KNOX, JH .
CHROMATOGRAPHIA, 1977, 10 (06) :279-289
[4]   OPTIMIZATION AND EVALUATION OF THE PERFORMANCE OF ARRANGEMENTS FOR UV DETECTION IN HIGH-RESOLUTION SEPARATIONS USING FUSED-SILICA CAPILLARIES [J].
BRUIN, GJM ;
STEGEMAN, G ;
VANASTEN, AC ;
XU, X ;
KRAAK, JC ;
POPPE, H .
JOURNAL OF CHROMATOGRAPHY, 1991, 559 (1-2) :163-181
[5]   PREPARATION OF OPEN-TUBULAR COLUMNS FOR REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
CREGO, AL ;
DIEZMASA, JC ;
DABRIO, MV .
ANALYTICAL CHEMISTRY, 1993, 65 (11) :1615-1621
[6]   FABRICATION OF COLUMNS FOR OPEN-TUBULAR LIQUID-CHROMATOGRAPHY USING PHOTOPOLYMERIZATION OF ACRYLATES [J].
EGUCHI, S ;
KLOOSTERBOER, JG ;
ZEGERS, CPG ;
SCHOENMAKERS, PJ ;
TOCK, PPH ;
KRAAK, JC ;
POPPE, H .
JOURNAL OF CHROMATOGRAPHY, 1990, 516 (02) :301-312
[7]  
EGUCHI S, 1988, 6318 PHIL RES LAB RE
[8]   STUDY OF POLYORGANOSILOXANES (NATIVE AND SOLVENT SWOLLEN) FOR THE PREPARATION OF NARROW (5-15 MU-M ID) AND LONG (1-6 M) OPEN-TUBULAR COLUMNS IN REVERSED-PHASE LIQUID-CHROMATOGRAPHY [J].
GOHLIN, K ;
LARSSON, M .
JOURNAL OF CHROMATOGRAPHY, 1993, 645 (01) :41-56
[9]   PREPARATION AND EVALUATION OF CROSS-LINKED POLYACRYLATE STATIONARY PHASES FOR OPEN-TUBULAR LIQUID-CHROMATOGRAPHY [J].
RUAN, Y ;
FEENSTRA, G ;
KRAAK, JC ;
POPPE, H .
CHROMATOGRAPHIA, 1993, 35 (9-12) :597-606
[10]  
Schoenmakers P.J., 1986, OPTIMIZATION CHROMAT