HIGH-FIELD MR MICROSCOPY USING FAST SPIN-ECHOES

被引:25
作者
ZHOU, XH [1 ]
COFER, GP [1 ]
SUDDARTH, SA [1 ]
JOHNSON, GA [1 ]
机构
[1] DUKE UNIV,MED CTR,DEPT RADIOL,CTR IN VIVO MICROSCOPY,BOX 3302,DURHAM,NC 27710
关键词
MR MICROSCOPY; FAST SPIN ECHO; SAMPLING SCHEMES;
D O I
10.1002/mrm.1910300110
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Fast spin-echo imaging has been investigated with attention to the requirements and opportunities for high-field MR microscopy. Two- and three-dimensional versions were implemented at 2.0 T, 7.1 T, and 9.4 T. At these fields, at least eight echoes were collectable with a 10 ms TE from fixed tissue specimens and living animals, giving an eightfold improvement in imaging efficiency. To reduce the phase-encoding gradient amplitude and its duty cycle, a modified pulse sequence with phase accumulation was developed. Images obtained using this pulse sequence exhibited comparable signal-to-noise (SNR) to those obtained from the conventional fast spin-echo pulse sequences. Signal losses due to imperfections in RF pulses and lack of phase rewinders were offset in this sequence by reduced diffusion losses incurred with the gradients required for MR microscopy. Image SNR, contrast, edge effects and spatial resolution for three k-space sampling schemes were studied experimentally and theoretically. One method of sampling k-space, 4-GROUP FSE, was found particularly useful in producing varied T2 contrast at high field. Two-dimensional images of tissue specimens were obtained in a total acquisition time of 1 to 2 min with in-plane resolution between 30 to 70 pm, and 3D images with 256(3) arrays were acquired from fixed rat brain tissue (isotropic voxel = 70 mum) and a living rat (isotropic voxel = 117 mum) in approximately 4.5 h.
引用
收藏
页码:60 / 67
页数:8
相关论文
共 21 条
[1]   A PROBE FOR SPECIMEN MAGNETIC-RESONANCE MICROSCOPY [J].
BANSON, ML ;
COFER, GP ;
BLACK, R ;
JOHNSON, GA .
INVESTIGATIVE RADIOLOGY, 1992, 27 (02) :157-164
[2]   SUSCEPTIBILITY-LIMITED RESOLUTION IN NUCLEAR-MAGNETIC-RESONANCE MICROSCOPY [J].
CALLAGHAN, PT .
JOURNAL OF MAGNETIC RESONANCE, 1990, 87 (02) :304-318
[3]   DIFFUSION-LIMITED RESOLUTION IN NUCLEAR MAGNETIC-RESONANCE MICROSCOPY [J].
CALLAGHAN, PT ;
ECCLES, CD .
JOURNAL OF MAGNETIC RESONANCE, 1988, 78 (01) :1-8
[4]   EFFECTS OF DIFFUSION ON FREE PRECESSION IN NUCLEAR MAGNETIC RESONANCE EXPERIMENTS [J].
CARR, HY ;
PURCELL, EM .
PHYSICAL REVIEW, 1954, 94 (03) :630-638
[5]   FAST SPIN-ECHO STUDIES OF CONTRAST AND SMALL-LESION DEFINITION IN A LIVER-METASTASIS PHANTOM [J].
CHIEN, D ;
MULKERN, RV .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1992, 2 (04) :483-487
[6]   NUCLEAR MAGNETIC-RESONANCE MICROSCOPY WITH 4-MU-M RESOLUTION - THEORETICAL-STUDY AND EXPERIMENTAL RESULTS [J].
CHO, ZH ;
AHN, CB ;
JUH, SC ;
LEE, HK ;
JACOBS, RE ;
LEE, S ;
YI, JH ;
JO, JM .
MEDICAL PHYSICS, 1988, 15 (06) :815-824
[7]  
HAASE A, 1985, 4TH ANN M SOC MAGN R, P980
[8]   A VENTILATOR FOR MAGNETIC-RESONANCE-IMAGING [J].
HEDLUND, LW ;
DEITZ, J ;
NASSAR, R ;
HERFKENS, R ;
VOCK, P ;
DAHLKE, J ;
KUBEK, R ;
EFFMANN, EL ;
PUTMAN, CE .
INVESTIGATIVE RADIOLOGY, 1986, 21 (01) :18-23
[9]   RARE IMAGING - A FAST IMAGING METHOD FOR CLINICAL MR [J].
HENNIG, J ;
NAUERTH, A ;
FRIEDBURG, H .
MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (06) :823-833
[10]   MULTIECHO IMAGING SEQUENCES WITH LOW REFOCUSING FLIP ANGLES [J].
HENNIG, J .
JOURNAL OF MAGNETIC RESONANCE, 1988, 78 (03) :397-407