Intra- and interobserver reliability analysis of digital radiographic measurements for pediatric orthopedic parameters using a novel PACS integrated computer software program

被引:68
作者
Segev, Eitan [1 ]
Hemo, Yoram [1 ]
Wientroub, Shlomo [1 ]
Ovadia, Dror [1 ]
Fishkin, Michael [1 ]
Steinberg, David M. [1 ,2 ]
Hayek, Shlomo [1 ]
机构
[1] Tel Aviv Univ, Dana Childrens Hosp, Sackler Fac Med, Tel Aviv Sourasky Med Ctr, 6 Weizmann St, IL-64239 Tel Aviv, Israel
[2] Tel Aviv Univ, Sch Math Sci, Dept Stat & Operat Res, Tel Aviv, Israel
关键词
Intra- and interobserver reliability; Digital radiographic measurements; Pediatric orthopedic parameters; PACS integrated computer software;
D O I
10.1007/s11832-010-0259-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background The between-observer reliability of repeated anatomic assessments in pediatric orthopedics relies on the precise definition of bony landmarks for measuring angles, indexes, and lengths of joints, limbs, and spine. We have analyzed intra-and interobserver reliability with a new digital measurement system (TraumaCad Wizard (TM)). Methods Five pediatric orthopedic surgeons measured 50 digital radiographs on three separate days using the TraumaCad system. There were 10 anterior-posterior (AP) pelvic views from developmental dysplasia of the hip (DDH) patients, 10 AP pelvic views from cerebral palsy (CP) patients, 10 AP standing view of the lower limb radiographs from leg length discrepancy (LLD) patients, and 10 AP and 10 lateral spine X-rays from scoliosis patients. All standing view of the lower limb radiographs were calibrated by the software to allow for accurate length measurements, using as reference a 1-inch metal ball placed at the level of the bone. Each observer performed 540 measurements (totaling 2,700). We estimated intra-and interobserver standard deviations for measurements in all categories by specialists and nonspecialists. The intraclass correlation coefficient (ICC) summarized the overall accuracy and precision of the measurement process relative to subject variation. We examined whether the relative accuracy of a measurement is adversely affected by the number of bony landmarks required for making the measurement. Results The overall ICC was >0.74 for 13 out of 18 measurements. Accuracy of the acetabular index for DDH was greater than for CP and relatively low for the center-edge angle in CP. Accuracy for bone length was better than for joint angulations in LLD and for the Cobb angle in AP views compared to lateral views for scoliosis. There were no clinically important biases, and most of the differences between specialists and nonspecialists were nonsignificant. The correlation between the results according to the number of bony landmarks that needed to be identified was also nonsignificant. Conclusions Digital measurements with the TraumaCad system are reliable in terms of intra-and interobserver variability, making it a useful method for the analysis of pathology on radiographs in pediatric orthopedics.
引用
收藏
页码:331 / 341
页数:11
相关论文
共 11 条
[1]
How should the acetabular angle of sharp be measured on a pelvic radiograph? [J].
Agus, H ;
Biçimoglu, A ;
Ömeroglu, H ;
Tümer, Y .
JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2002, 22 (02) :228-231
[2]
Radiographic Evaluation of the Hip has Limited Reliability [J].
Clohisy, John C. ;
Carlisle, John C. ;
Trousdale, Robert ;
Kim, Young-Jo ;
Beaule, Paul E. ;
Morgan, Patrick ;
Steger-May, Karen ;
Schoenecker, Perry L. ;
Millis, Michael .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2009, 467 (03) :666-675
[3]
Manual versus digital radiographic measurements in acetabular dysplasia [J].
Halanski, Mathew A. ;
Noonan, Kenneth J. ;
Hebert, Mathew ;
Nemeth, Blaise A. ;
Mann, David C. ;
Leverson, Glen .
ORTHOPEDICS, 2006, 29 (08) :724-726
[4]
Hankemeier S, 2006, Comput Aided Surg, V11, P81, DOI 10.3109/10929080600628985
[5]
Herring JA, 2008, TACHDJIANS PEDIAT OR, P358
[6]
Reliability of radiological measurements in the assessment of hip dysplasia in adults [J].
Nelitz, M ;
Guenther, KP ;
Gunkel, S ;
Puhl, W .
BRITISH JOURNAL OF RADIOLOGY, 1999, 72 (856) :331-334
[7]
Analysis of a radiographic assessment method of acetabular cover in developmental dysplasia of the hip [J].
Ömeroglu, H ;
Agus, H ;
Bicimoglu, A ;
Tümer, Y .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2002, 122 (06) :334-337
[8]
Paley D, 2002, PRINCIPLES DEFORMITY, P8
[9]
Quantification of axial alignment of the lower extremity on conventional and digital total leg radiographs [J].
Sailer, J ;
Scharitzer, M ;
Peloschek, P ;
Giurea, A ;
Imhof, H ;
Grampp, S .
EUROPEAN RADIOLOGY, 2005, 15 (01) :170-173
[10]
Schmidt Gary L, 2004, J Knee Surg, V17, P141