SIMULTANEOUS DETERMINATION OF C, H, N, O, F, CL, BR, AND S IN GAS-CHROMATOGRAPHIC EFFLUENT BY FOURIER-TRANSFORM RED NEAR-INFRARED ATOMIC EMISSION-SPECTROSCOPY

被引:36
作者
PIVONKA, DE [1 ]
FATELEY, WG [1 ]
FRY, RC [1 ]
机构
[1] KANSAS STATE UNIV AGR & APPL SCI,DEPT CHEM,WILLARD HALL,MANHATTAN,KS 66506
关键词
CARBON - Spectroscopic Analysis - CHROMATOGRAPHIC ANALYSIS - PLASMAS - Applications - SPECTROSCOPY; EMISSION - Applications - SULFUR - Spectroscopic Analysis;
D O I
10.1366/0003702864509123
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A high-powered, atmospheric-pressure, helium microwave-induced plasma (MIP) is used as the interface between a gas chromatograph (GC) and a Fourier transform near-infrared (FT-NIR) emission spectrometer. By the collection of a series of time-resolved interferograms when organic compounds elute from the GC into the plasma, a complete account of both spectral and chromatographic activity is recorded. Computer-generated, element-specific chromatographic reconstructions for each of eight different nonmentals are obtained from a single injection of chemical mixture.
引用
收藏
页码:291 / 297
页数:7
相关论文
共 15 条
[1]   DETERMINATION OF IODINATED HERBICIDE RESIDUES AND METABOLITES BY GAS CHROMATOGRAPHY USING EMISSION SPECTROMETRIC DETECTOR [J].
BACHE, CA ;
LISK, DJ .
ANALYTICAL CHEMISTRY, 1966, 38 (06) :783-&
[2]  
BEENAKKER CIM, 1976, SPECTROCHIM ACTA B, V31, P438
[3]   CONSIDERATIONS IN THE DESIGN OF A MICROWAVE INDUCED PLASMA UTILIZING THE TM010 CAVITY FOR OPTICAL-EMISSION SPECTROSCOPY [J].
BOLLOKAMARA, A ;
CODDING, EG .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1981, 36 (10) :973-982
[4]   MICROWAVE-EXCITED EMISSIVE DETECTOR IN GAS-PHASE CHROMATOGRAPHY .I. SOME STUDIES WITH SULPHUR COMPOUNDS [J].
DAGNALL, RM ;
PRATT, SJ ;
WEST, TS ;
DEANS, DR .
TALANTA, 1969, 16 (07) :797-&
[5]   INTERFEROMETRIC DETECTION OF NEAR-INFRARED NONMETAL ATOMIC EMISSION FROM A MICROWAVE-INDUCED PLASMA [J].
FREEMAN, JE ;
HIEFTJE, GM .
APPLIED SPECTROSCOPY, 1985, 39 (02) :211-214
[6]   AN INTERNALLY TUNED TM010 MICROWAVE RESONANT CAVITY FOR MODERATE POWER MICROWAVE-INDUCED PLASMAS [J].
HAAS, DL ;
CARNAHAN, JW ;
CARUSO, JA .
APPLIED SPECTROSCOPY, 1983, 37 (01) :82-85
[7]   SENSITIVE SELECTIVE GAS CHROMATOGRAPHY DETECTOR BASED ON EMISSION SPECTROMETRY OF ORGANIC COMPOUNDS [J].
MCCORMACK, AJ ;
TONG, SC ;
COOKE, WD .
ANALYTICAL CHEMISTRY, 1965, 37 (12) :1470-+
[8]   DETERMINATION OF TRIHALOMETHANES IN DRINKING-WATER BY GAS-CHROMATOGRAPHY WITH A MICROWAVE PLASMA EMISSION DETECTOR [J].
QUIMBY, BD ;
DELANEY, MF ;
UDEN, PC ;
BARNES, RM .
ANALYTICAL CHEMISTRY, 1979, 51 (07) :875-880
[9]  
SCHLEISMAN AJJ, 1984, J PHYS CHEM, V88, P389
[10]   SOME NEAR-IR SPECTRAL EMISSION CHARACTERISTICS OF THE INDUCTIVELY COUPLED PLASMA [J].
STUBLEY, EA ;
HORLICK, G .
APPLIED SPECTROSCOPY, 1984, 38 (02) :162-168