PERSONAL-COMPUTER-BASED SYSTEM FOR ELECTRON-BEAM X-RAY-MICROANALYSIS OF BIOLOGICAL SAMPLES

被引:21
作者
FOSTER, MC
SAUBERMANN, AJ
机构
[1] Department of Anaesthesiology, SUNY at Stony Brook, New York, 11794-8480, Stony Brook
关键词
ELECTRON PROBE MICROANALYSIS; X-RAY MICROANALYSIS; X-RAY EMISSION SPECTROSCOPY; PERSONAL COMPUTER HARDWARE; PERSONAL COMPUTER SOFTWARE; DIGITAL ELEMENTAL IMAGES;
D O I
10.1111/j.1365-2818.1991.tb03097.x
中图分类号
TH742 [显微镜];
学科分类号
摘要
A system based on a personal computer has been developed which provides a relatively inexpensive way to equip an electron microscopy laboratory for quantitative elemental analyses of cryosectioned biological samples. This system demonstrates the feasibility of making an X-ray analyser from a personal computer, together with commercially available hardware and software components. Hardware and software have been assembled to drive the beam in a scanning electron microscope, collect and analyse X-ray spectra, and save, retrieve, and analyse data. Our software provides a menu-controlled user interface to direct spectra acquisition and analysis. Spot analyses, video images, and quantitative elemental images may be obtained and results transferred in ASCII format to other computers. Wet weight, as well as dry weight, concentrations are calculated, if measurements were made of areas of the hydrated sample before it was freeze-dried. Grey-level copies of video and quantitative elemental images may be made on a laser printer.
引用
收藏
页码:367 / 373
页数:7
相关论文
共 20 条
[1]   APPLICATION OF SCANNING ELECTRON-MICROSCOPY TO X-RAY-ANALYSIS OF FROZEN-HYDRATED SECTIONS .3. ELEMENTAL CONTENT OF CELLS IN THE RAT RENAL PAPILLARY TIP [J].
BULGER, RE ;
BEEUWKES, R ;
SAUBERMANN, AJ .
JOURNAL OF CELL BIOLOGY, 1981, 88 (02) :274-280
[2]   QUANTITATIVE X-RAY MAPPING OF BIOLOGICAL CRYOSECTIONS [J].
FIORI, CE ;
LEAPMAN, RD ;
SWYT, CR ;
ANDREWS, SB .
ULTRAMICROSCOPY, 1988, 24 (2-3) :237-249
[3]  
FOSTER MC, 1989, MICROBEAM ANAL, P137
[4]  
GORLEN KE, 1984, REV SCI INSTRUM, V55, P912, DOI 10.1063/1.1137864
[5]   BIOLOGICAL X-RAY-MICROANALYSIS [J].
HALL, TA .
JOURNAL OF MICROSCOPY, 1979, 117 (SEP) :145-163
[6]   MULTIFUNCTIONAL MINICOMPUTER PROGRAM PROVIDING QUANTITATIVE AND DIGITAL X-RAY-MICROANALYSIS OF CRYOSECTIONED BIOLOGICAL TISSUE FOR THE INEXPERIENCED ANALYST [J].
HEYMAN, RV ;
SAUBERMANN, AJ .
JOURNAL OF ELECTRON MICROSCOPY TECHNIQUE, 1987, 5 (04) :315-345
[7]  
INGRAM P, 1988, MICROBEAM ANAL 1988, P433
[8]   ANALYSIS OF DIRECTLY FROZEN MACROMOLECULES AND TISSUES IN THE FIELD-EMISSION STEM [J].
LEAPMAN, RD ;
ANDREWS, SB .
JOURNAL OF MICROSCOPY-OXFORD, 1991, 161 :3-19
[9]  
LOPACHIN R M, 1990, Society for Neuroscience Abstracts, V16, P475
[10]   DISTRIBUTION OF ELEMENTS IN RAT PERIPHERAL AXONS AND NERVE-CELL BODIES DETERMINED BY X-RAY MICROPROBE ANALYSIS [J].
LOPACHIN, RM ;
LOWERY, J ;
EICHBERG, J ;
KIRKPATRICK, JB ;
CARTWRIGHT, J ;
SAUBERMANN, AJ .
JOURNAL OF NEUROCHEMISTRY, 1988, 51 (03) :764-775