PROPOSED ROOM-TEMPERATURE DETECTOR FOR GRAVITATIONAL-RADIATION FROM GALACTIC SOURCES

被引:6
作者
BORDONI, F
KARIM, M
BOCKO, MF
MENGXI, T
机构
[1] UNIV TOR VERGATA,DIPARTIMENTO FIS,I-00173 ROME,ITALY
[2] UNIV ROCHESTER,DEPT ELECT ENGN,ROCHESTER,NY 14627
[3] ZHONGSHAN UNIV,DEPT PHYS,GUANGZHOU 510275,PEOPLES R CHINA
[4] ST JOHN FISHER COLL,DEPT PHYS,ROCHESTER,NY 14618
来源
PHYSICAL REVIEW D | 1990年 / 42卷 / 08期
关键词
D O I
10.1103/PhysRevD.42.2952
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
A room-temperature resonant-bar gravitational-radiation detector instrumented with a tunneling transducer may be sensitive enough to register supernovae events from the Galaxy. The key element in the new approach is the tunneling transducer, which is a quantum-limited electromechanical amplifier even at room temperature. We propose a design for a 2000-kg room-temperature, three-mode detector with a bandwidth of 200 Hz and a noise temperature of 100 mK, which corresponds to an rms strain sensitivity of h4×10-18 © 1990 The American Physical Society.
引用
收藏
页码:2952 / 2955
页数:4
相关论文
共 9 条
[1]   VACUUM TUNNELING PROBE - A NONRECIPROCAL, REDUCED-BACK-ACTION TRANSDUCER [J].
BOCKO, MF ;
STEPHENSON, KA ;
KOCH, RH .
PHYSICAL REVIEW LETTERS, 1988, 61 (06) :726-729
[2]  
BORDONI F, 1989, 5TH P M GROSSM M GEN, P1877
[3]  
BORDONI F, UNPUB
[4]   VERY HIGH Q-FACTOR RESONATORS IN MONOCRYSTALLINE SILICON [J].
BUSER, RA ;
DEROOIJ, NF .
SENSORS AND ACTUATORS A-PHYSICAL, 1990, 21 (1-3) :323-327
[5]   COMPARISON OF BAR AND INTERFEROMETER SENSITIVITIES TO SOURCES OF TRANSIENT GRAVITATIONAL-RADIATION [J].
DEWEY, D .
PHYSICAL REVIEW D, 1987, 36 (06) :1577-1586
[6]  
LAM CC, 1979, THESIS U ROCHESTER
[7]   PROPOSAL FOR A NOVEL GRAVITATIONAL-WAVE SENSOR [J].
NIKSCH, M ;
BINNIG, G .
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A-VACUUM SURFACES AND FILMS, 1988, 6 (02) :470-471
[8]   WIDEBAND BAR DETECTORS OF GRAVITATIONAL-RADIATION [J].
RICHARD, JP .
PHYSICAL REVIEW LETTERS, 1984, 52 (03) :165-167
[9]  
Thorne K. S., 1987, 300 YEARS GRAVITATIO