INTERPRETATION TIME OF SERIAL CHEST CT EXAMINATIONS WITH STACKED-METAPHOR WORKSTATION VERSUS FILM ALTERNATOR

被引:9
作者
BEARD, DV
MOLINA, PL
MULLER, KE
DENELSBECK, KM
HEMMINGER, BM
PERRY, JR
BRAEUNING, MP
GLUECK, DH
BIDGOOD, WD
MAURO, M
SEMELKA, RC
WILLMS, AS
WARSHAUER, D
PISANO, ED
机构
[1] UNIV N CAROLINA,SCH MED,DEPT RADIOL,CHAPEL HILL,NC 27514
[2] UNIV N CAROLINA,SCH MED,DEPT COMP SCI,CHAPEL HILL,NC 27514
[3] UNIV N CAROLINA,SCH MED,DEPT BIOSTAT,CHAPEL HILL,NC 27514
关键词
COMPUTED TOMOGRAPHY (CT); IMAGE DISPLAY AND RECORDING; DIAGNOSTIC RADIOLOGY; OBSERVER PERFORMANCE; RECEIVER OPERATING CHARACTERISTIC CURVE (ROC); WORKSTATION;
D O I
10.1148/radiology.197.3.7480751
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: Interpretation time of serial staging chest CT cases, which each contained current and previous examinations, with a simple prototype workstation called filmstack was experimentally compared with interpretation time with a film alternator. MATERIALS AND METHODS: The filmstack displayed a ''stack'' of,sections for each examination; user controls allowed rapid selection of preset attenuation windows and both synchronized and unsynchronized scrolling. Eight radiologists were timed as they used the filmstack and the film alternator to interpret four ergonomically complex serial CT cases. RESULTS: All reports dictated on the basis of findings with filmstack and film were of acceptable clinical accuracy. The time to examine a case with filmstack was significantly faster than the time with film, including the time to load and unload the alternator (99% confidence [P = .01]). There was no statistically significant difference in interpretation time between filmstack and prehung film. CONCLUSION: Use of a low-cost stacked CT workstation with a single 1,024 x 1,024 monitor is an effective means of interpreting cases that require comparison of multiple CT examinations.
引用
收藏
页码:753 / 758
页数:6
相关论文
共 16 条
[1]   IMPROVED FINANCIAL MANAGEMENT OF THE RADIOLOGY DEPARTMENT WITH A MICROCOSTING SYSTEM [J].
ARENSON, RL ;
VANDERVOORDE, F ;
STEVENS, JF .
RADIOLOGY, 1988, 166 (01) :255-259
[2]   THE DIGITAL IMAGING WORKSTATION [J].
ARENSON, RL ;
CHAKRABORTY, DP ;
SESHADRI, SB ;
KUNDEL, HL .
RADIOLOGY, 1990, 176 (02) :303-315
[3]  
Beard D, 1990, J Digit Imaging, V3, P152
[4]  
Beard D V, 1990, J Digit Imaging, V3, P230
[5]  
Beard D V, 1994, J Digit Imaging, V7, P189
[6]   INTERPRETATION OF CT STUDIES - SINGLE-SCREEN WORKSTATION VERSUS FILM ALTERNATOR [J].
BEARD, DV ;
HEMMINGER, BM ;
PERRY, JR ;
MAURO, MA ;
MULLER, KE ;
WARSHAUER, DM ;
SMITH, MA ;
ZITO, AJ .
RADIOLOGY, 1993, 187 (02) :565-569
[7]  
BEARD DV, 1994, J DIGIT IMAGING, V7, P1
[8]  
BERBAUM KS, 1990, J COMPUT ASSIST TOMO, V4, P853
[9]   MR EXAMINATION OF THE KNEE - INTERPRETATION WITH MULTISCREEN DIGITAL WORKSTATION VS HARD-COPY FORMAT [J].
BROWN, JJ ;
MALCHOW, SC ;
TOTTY, WG ;
WILSON, AJ ;
LEE, JKT ;
VANNIER, MW ;
JOST, RG .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 157 (01) :81-85
[10]  
Card S. K., 1983, PSYCHOL HUMAN COMPUT