INTERPRETATION OF CT STUDIES - SINGLE-SCREEN WORKSTATION VERSUS FILM ALTERNATOR

被引:23
作者
BEARD, DV
HEMMINGER, BM
PERRY, JR
MAURO, MA
MULLER, KE
WARSHAUER, DM
SMITH, MA
ZITO, AJ
机构
[1] UNIV N CAROLINA,SCH MED,DEPT COMP SCI,CHAPEL HILL,NC 27599
[2] UNIV N CAROLINA,SCH MED,DEPT BIOSTAT,CHAPEL HILL,NC 27599
[3] UNIV N CAROLINA,SCH MED,DEPT SURG,CHAPEL HILL,NC 27599
关键词
COMPUTED TOMOGRAPHY (CT); IMAGE DISPLAY AND RECORDING; DIAGNOSTIC RADIOLOGY; OBSERVER PERFORMANCE; IMAGES; DISPLAY; INTERPRETATION; PICTURE ARCHIVING AND COMMUNICATION SYSTEM;
D O I
10.1148/radiology.187.2.8475309
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A prototype single-screen workstation with a 2,048 x 2,560-pixel high-brightness monitor, 0.11-second image display time, and simple ergonomic design was compared to a conventional horizontal film alternator in diagnostic interpretation of chest computed tomography (CT) studies. Four radiologists used either the workstation or film alternator in interpretation of studies obtained in 10 patients. A counterbalanced within-subject repeated measures experimental design was used. Response times were analyzed for both methods of interpretation. Grades of excellent, acceptable, and unacceptable were assigned by a blinded ''grader'' to reports of the radiologists. The average time needed for an interpretation at the workstation was 5.65 minutes. No interpretations were graded unacceptable. Retrospective power analysis showed that 16 observers rather than four would have been required to show that use of the workstation was faster than the alternator. With this 95% confidence interval, the workstation interpretation time is clinically equivalent to that with the alternator. These data show that this type of workstation has practical application in interpretation of CT, magnetic resonance imaging, and ultrasound studies.
引用
收藏
页码:565 / 569
页数:5
相关论文
共 23 条
  • [1] IMPROVED FINANCIAL MANAGEMENT OF THE RADIOLOGY DEPARTMENT WITH A MICROCOSTING SYSTEM
    ARENSON, RL
    VANDERVOORDE, F
    STEVENS, JF
    [J]. RADIOLOGY, 1988, 166 (01) : 255 - 259
  • [2] THE DIGITAL IMAGING WORKSTATION
    ARENSON, RL
    CHAKRABORTY, DP
    SESHADRI, SB
    KUNDEL, HL
    [J]. RADIOLOGY, 1990, 176 (02) : 303 - 315
  • [3] Beard D, 1990, J Digit Imaging, V3, P152
  • [4] Beard D, 1990, J Digit Imaging, V3, P108
  • [5] Beard D V, 1990, J Digit Imaging, V3, P230
  • [6] BEARD DV, 1992, 1992 P S COMP APPL R, P588
  • [7] EVALUATION OF A PACS WORKSTATION FOR ASSESSMENT OF BODY CT STUDIES
    BERBAUM, KS
    FRANKEN, EA
    HONDA, H
    MCGUIRE, C
    WEIS, RR
    BARLOON, T
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1990, 14 (05) : 853 - 858
  • [8] MR EXAMINATION OF THE KNEE - INTERPRETATION WITH MULTISCREEN DIGITAL WORKSTATION VS HARD-COPY FORMAT
    BROWN, JJ
    MALCHOW, SC
    TOTTY, WG
    WILSON, AJ
    LEE, JKT
    VANNIER, MW
    JOST, RG
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 157 (01) : 81 - 85
  • [9] Card S. K., 1983, PSYCHOL HUMAN COMPUT
  • [10] THE INFORMATION CAPACITY OF THE HUMAN MOTOR SYSTEM IN CONTROLLING THE AMPLITUDE OF MOVEMENT
    FITTS, PM
    [J]. JOURNAL OF EXPERIMENTAL PSYCHOLOGY, 1954, 47 (06): : 381 - 391