CHARACTERIZATION OF BAND BROADENING IN CAPILLARY ELECTROPHORESIS DUE TO NONUNIFORM CAPILLARY GEOMETRIES

被引:62
作者
XUE, YJ
YEUNG, ES
机构
[1] IOWA STATE UNIV SCI & TECHNOL,US DOE,AMES LAB,AMES,IA 50011
[2] IOWA STATE UNIV SCI & TECHNOL,DEPT CHEM,AMES,IA 50011
关键词
D O I
10.1021/ac00093a007
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple procedure for creating a region of expanded diameter os a capillary column is described. This bubble-shaped on-column flow cell provides an extended path length for absorption detection in capillary electrophoresis (CE) or capillary chromatography. To properly probe the compressed analyte zone in this region, a laser beam with a noise-cancellation circuit was used. Up to 8X enhancement in signal was achieved. Characterization of CE flow profiles in the bubble-shaped region shows that distortions in flow lead to band broadening, especially when a rapid change in diameter over a short column length is present. The electric field lines are, however, still oriented axially throughout the bubble region. Similar disturbances are expected in any coupling schemes in CE that involve a geometry change, in addition to multipath effects and distortions in the electric field.
引用
收藏
页码:3575 / 3580
页数:6
相关论文
共 30 条
[11]  
LIN S, 1993, ANAL CHIM ACTA, V283, P747
[12]   USE OF AN ON-COLUMN FRACTURE IN CAPILLARY ZONE ELECTROPHORESIS FOR SAMPLE INTRODUCTION [J].
LINHARES, MC ;
KISSINGER, PT .
ANALYTICAL CHEMISTRY, 1991, 63 (18) :2076-2078
[13]   CONCENTRATION DISTRIBUTIONS IN FREE ZONE ELECTROPHORESIS [J].
MIKKERS, FEP ;
EVERAERTS, FM ;
VERHEGGEN, TPEM .
JOURNAL OF CHROMATOGRAPHY, 1979, 169 (FEB) :1-10
[14]   STUDY OF ZONE BROADENING IN OPTICALLY GATED HIGH-SPEED CAPILLARY ELECTROPHORESIS [J].
MOORE, AW ;
JORGENSON, JW .
ANALYTICAL CHEMISTRY, 1993, 65 (24) :3550-3560
[15]   OPTICAL IMPROVEMENTS OF A Z-SHAPED CELL FOR HIGH-SENSITIVITY UV ABSORBENCY DETECTION IN CAPILLARY ELECTROPHORESIS [J].
MORING, SE ;
REEL, RT ;
VANSOEST, REJ .
ANALYTICAL CHEMISTRY, 1993, 65 (23) :3454-3459
[16]   ENZYMOPHORESIS OF NUCLEIC-ACIDS BY TANDEM CAPILLARY ENZYME REACTOR-CAPILLARY ZONE ELECTROPHORESIS [J].
NASHABEH, W ;
ELRASSI, Z .
JOURNAL OF CHROMATOGRAPHY, 1992, 596 (02) :251-264
[17]   CHARACTERIZATION OF A POST-COLUMN REACTION LASER-INDUCED FLUORESCENCE DETECTOR FOR CAPILLARY ZONE ELECTROPHORESIS [J].
NICKERSON, B ;
JORGENSON, JW .
JOURNAL OF CHROMATOGRAPHY, 1989, 480 :157-168
[18]   CAPILLARY ELECTROPHORESIS IN 2-MU-M AND 5-MU-M DIAMETER CAPILLARIES - APPLICATION TO CYTOPLASMIC ANALYSIS [J].
OLEFIROWICZ, TM ;
EWING, AG .
ANALYTICAL CHEMISTRY, 1990, 62 (17) :1872-1876
[19]   ONLINE CONNECTOR FOR MICROCOLUMNS - APPLICATION TO THE ON-COLUMN ORTHO-PHTHALDIALDEHYDE DERIVATIZATION OF AMINO-ACIDS SEPARATED BY CAPILLARY ZONE ELECTROPHORESIS [J].
PENTONEY, SL ;
HUANG, XH ;
BURGI, DS ;
ZARE, RN .
ANALYTICAL CHEMISTRY, 1988, 60 (23) :2625-2629
[20]   OPEN-TUBULAR LIQUID-CHROMATOGRAPHY WITH SURFACTANT-ENHANCED ELECTROOSMOTIC FLOW [J].
PFEFFER, WD ;
YEUNG, ES .
ANALYTICAL CHEMISTRY, 1990, 62 (20) :2178-2182