COMPARISON OF 2 2ND-GENERATION ANTI-HEPATITIS-C VIRUS ELISA ON 21431 US BLOOD-DONOR SAMPLES

被引:57
作者
ANDERSON, SC
HATHAWAY, T
KURAMOTO, IK
HOLLAND, PV
GILCHER, R
KOCH, T
HOJVAT, S
机构
[1] OKLAHOMA BLOOD INST,OKLAHOMA CITY,OK
[2] ABBOTT LABS,CHICAGO,IL
关键词
ANTI-HCV; BLOOD DONOR; ENZYME IMMUNOASSAY; HEPATITIS C; HEPATITIS C ANTIBODY; RECOMBINANT IMMUNOBLOT ASSAY;
D O I
10.1111/j.1365-2893.1995.tb00072.x
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
We have compared two different second-generation (2.0) enzyme-linked immunosorbent assays (ELISA) for the presence of antibodies to hepatitis C virus (anti-HCV) in blood from volunteer, unpaid donors. At two separate blood centres, a total of 21431 donor samples were tested with Abbott Anti-HCV 2.0 ELISA and Ortho Anti-HCV 2.0 ELISA. Samples found to be repeatedly reactive were tested by supplemental/investigational assays, MATRIX HCV (Abbott) and anti-HCV RIBA II (Ortho/Chiron), to 'confirm' the presence of anti-HCV. Discordant ELISA samples were additionally tested by the polymerase chain reaction (PCR) for the presence of HCV RNA. The Abbott anti-HCV assay had a repeatedly reactive rate of 0.59% (127/21431) and the Ortho anti-HCV assay 0.51% (110/21431). Overall agreement between assays was 99.76%. 72/127 (56.7%) of Abbott repeatedly reactive samples confirmed on MATRIX and 61/127 (48.0%) on RIBAII; 70/110 (63 . 6%) of Ortho repeatedly reactivate samples confirmed on MATRIX and 61/110 (55.5%) on RIBA II, Discordant ELISA samples tested by PCR yielded negative results. Hence the two ELISA had equal sensitivity, as defined by detection of true positive samples; the slightly lower specificity of the Abbott Anti-HCV 2.0 ELISA may be owing to culling of donors with a false positive test by Ortho's Anti-HCV 1.0 and 2.0 ELISA tests (the routine tests in place at each blood centre). A sample found to be repeatedly reactive by two different ELISA tests for anti-HCV is likely to be a true positive and may not require further 'confirmatory' testing.
引用
收藏
页码:55 / 61
页数:7
相关论文
共 16 条
[1]   HEPATITIS-C VIRUS-INFECTION IN POSTTRANSFUSION HEPATITIS - AN ANALYSIS WITH 1ST-GENERATION AND 2ND-GENERATION ASSAYS [J].
AACH, RD ;
STEVENS, CE ;
HOLLINGER, FB ;
MOSLEY, JW ;
PETERSON, DA ;
TAYLOR, PE ;
JOHNSON, RG ;
BARBOSA, LH ;
NEMO, GJ .
NEW ENGLAND JOURNAL OF MEDICINE, 1991, 325 (19) :1325-1329
[2]  
Aoki S K, 1994, J Viral Hepat, V1, P73, DOI 10.1111/j.1365-2893.1994.tb00064.x
[3]  
AOKI SK, 1993, BLOOD, V82, P1000
[4]   COMPARISON OF 2 APPROVED ENZYME IMMUNOASSAYS FOR THE DETECTION OF ANTIBODIES TO THE HEPATITIS-C VIRUS IN 5216 UNITED-STATES BLOOD-DONORS [J].
BETLACH, B ;
ANDERSON, S ;
RODRIGUEZ, R ;
KURAMOTO, K ;
SAZAMA, K ;
HOLLAND, PV .
TRANSFUSION, 1992, 32 (02) :191-192
[5]  
DEBEENHOUWER H, 1992, VOX SANG, V63, P198
[6]   COMPARATIVE-EVALUATION OF SUPPLEMENTAL HEPATITIS-C VIRUS-ANTIBODY TEST SYSTEMS [J].
EVANS, CS ;
TOBLER, L ;
POLITO, A ;
STEWART, J ;
CHIEN, D ;
WILBER, J ;
QUAN, S ;
DELANEY, S ;
KUO, G ;
BUSCH, MP .
TRANSFUSION, 1992, 32 (05) :408-414
[7]   USE OF AMINOTRANSFERASE, HEPATITIS-C ANTIBODY, AND HEPATITIS-C POLYMERASE CHAIN-REACTION RNA ASSAYS TO ESTABLISH THE DIAGNOSIS OF HEPATITIS-C VIRUS-INFECTION IN A DIAGNOSTIC VIROLOGY LABORATORY [J].
GRETCH, D ;
LEE, W ;
COREY, L .
JOURNAL OF CLINICAL MICROBIOLOGY, 1992, 30 (08) :2145-2149
[8]   DETECTION OF HEPATITIS-C VIRUS-RNA - COMPARISON OF ONE-STAGE POLYMERASE CHAIN-REACTION (PCR) WITH NESTED-SET PCR [J].
GRETCH, DR ;
WILSON, JJ ;
CARITHERS, RL ;
DELAROSA, C ;
HAN, JH ;
COREY, L .
JOURNAL OF CLINICAL MICROBIOLOGY, 1993, 31 (02) :289-291
[9]   CHARACTERIZATION OF THE TERMINAL REGIONS OF HEPATITIS-C VIRAL-RNA - IDENTIFICATION OF CONSERVED SEQUENCES IN THE 5' UNTRANSLATED REGION AND POLY(A) TAILS AT THE 3' END [J].
HAN, JH ;
SHYAMALA, V ;
RICHMAN, KH ;
BRAUER, MJ ;
IRVINE, B ;
URDEA, MS ;
TEKAMPOLSON, P ;
KUO, G ;
CHOO, QL ;
HOUGHTON, M .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1991, 88 (05) :1711-1715
[10]   INCREASED DETECTION OF HEPATITIS C VIRUS (HCV)-INFECTED BLOOD-DONORS BY A MULTIPLE-ANTIGEN HCV ENZYME-IMMUNOASSAY [J].
KLEINMAN, S ;
ALTER, H ;
BUSCH, M ;
HOLLAND, P ;
TEGTMEIER, G ;
NELLES, M ;
LEE, S ;
PAGE, E ;
WILBER, J ;
POLITO, A .
TRANSFUSION, 1992, 32 (09) :805-813