UNCONVENTIONAL PEDICLE SPINAL INSTRUMENTATION - THE BOMBAY EXPERIENCE

被引:9
作者
ANAND, N
TANNA, DD
机构
[1] Department of Orthopaedic Surgery, B.Y.L.Nair Ch. Hospital, T.N. Medical College, Bombay
关键词
ANTERIOR COLUMN AUGMENTATION; DEVELOPING COUNTRIES; PEDICLE SPINAL INSTRUMENTATION; POSTERIOR LUMBAR INTERBODY FUSION; POSTEROLATERAL FUSION; UNCONVENTIONAL;
D O I
10.1097/00007632-199410000-00004
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. A retrospective study of all patients who underwent spinal fusion between 1986 to 1989 with inexpensive, locally made unconventional pedicle spinal instrumentation systems was undertaken. Implants were made with passivated 316L stainless steel, and a single level of instrumentation cost $30. Objectives. To demonstrate that simple, cheap pedicle instrumentation systems are as effective as the conventionally available expensive systems, provided proper anterior column support is maintained. Methods. Ninety out of 102 patients were available for review. Average follow-up was 41 months (range, 22 to 60 months). Implant failures, screw placement, fusion rates, infection, neurologic deficit due to the implant, patient satisfaction, and the benefit of anterior column grafting with the unconventional pedicle spinal instrumentation systems in the long term were evaluated. Results. Forty-four out of 467 screws failed (9%) in 16 patients, seven of whom were symptomatic. There were no plate failures. On comparing burst fractures with (n = 12) and without (n = 10) anterior column grafting, the latter group had a significant increase in implant failures, loss of sagittal alignment, and the time required to fusion. Overall, fusion occurred within 6.5 months. Conclusions. Anterior column reconstruction in anterior column-deficient spines will re-create the normal biomechanics and significantly reduce the incidence of implant failures and loss of sagittal alignment with these systems. Pedicle screw failure in itself is not necessarily associated with a bad result. These inexpensive, locally made unconventional systems, with the proper understanding of biomechanics and creation of appropriate load-sharing constructs, are as good as the conventional systems available today.
引用
收藏
页码:2150 / 2158
页数:9
相关论文
共 27 条
  • [1] Ashman R.B., Galpin R.D., Corin J.D., Johnston C., Biomechanical analysis of pedicle screw instrumentation systems in a corpectomy model, Spine, 14, pp. 1398-1405, (1989)
  • [2] Bhojraj S.Y., Archik S.G., Early results of unconventional pedicular screwplate fixations: The Indian experience, Spine, 16, pp. 1192-1195, (1991)
  • [3] Daniaux H., Seykora P., Genelin A., Lang T., Kathrein A., Application of posterior plating and modifications in thoracolumbar spine injuries: Indications, techniques, and results, Spine, 16, 3S, (1991)
  • [4] Dean S., Hall B., Johnson R., Analysis of posterolateral lumbar fusion and VSP pedicle screw and plate fixation, Annual Meeting of the American Academy of Orthopaedic Surgeons, (1990)
  • [5] Ebelke D.K., Asher M.A., Neff J.R., Kraker D.P., Survivorship analysis of VSP instrumentation in the treatment of thoracolumbar and lumbar burst fractures, Spine, 16, 8, (1991)
  • [6] Esses S.I., Botsford D.J., Wright T., Bednar D., Bailey S., Operative treatment of spinal fractures with the AO internal fixator, Spine, 16, 3, (1991)
  • [7] Grubb S.A., Lipscomb H.J., Results of lumbosacral fusion for degenerative disc disease with and without instrumentation: Two to five year follow-up, Spine, 17, pp. 349-355, (1992)
  • [8] Jacobs R.R., Nordwall A., Nachemson A., Stability and strength provided by internal fixation systems for dorsolumbar spinal injuries, Clin Orthop, 171, pp. 300-308, (1982)
  • [9] Krag M.H., Beynnon B.D., Pope M.H., Frymoyer J.W., Haugh L.D., Weaver D.L., An internal fixator for posterior application to short segments of the thoracic, lumbar, or lumbosacral spinedesign and testing, Clin Orthop, 203, pp. 75-98, (1986)
  • [10] Krag M.H., Biomechanics of thoracolumbar spinal fixation: A review, Spine, 16, 3, pp. S84-S99, (1991)