UNCONVENTIONAL PEDICLE SPINAL INSTRUMENTATION - THE BOMBAY EXPERIENCE

被引:9
作者
ANAND, N
TANNA, DD
机构
[1] Department of Orthopaedic Surgery, B.Y.L.Nair Ch. Hospital, T.N. Medical College, Bombay
关键词
ANTERIOR COLUMN AUGMENTATION; DEVELOPING COUNTRIES; PEDICLE SPINAL INSTRUMENTATION; POSTERIOR LUMBAR INTERBODY FUSION; POSTEROLATERAL FUSION; UNCONVENTIONAL;
D O I
10.1097/00007632-199410000-00004
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. A retrospective study of all patients who underwent spinal fusion between 1986 to 1989 with inexpensive, locally made unconventional pedicle spinal instrumentation systems was undertaken. Implants were made with passivated 316L stainless steel, and a single level of instrumentation cost $30. Objectives. To demonstrate that simple, cheap pedicle instrumentation systems are as effective as the conventionally available expensive systems, provided proper anterior column support is maintained. Methods. Ninety out of 102 patients were available for review. Average follow-up was 41 months (range, 22 to 60 months). Implant failures, screw placement, fusion rates, infection, neurologic deficit due to the implant, patient satisfaction, and the benefit of anterior column grafting with the unconventional pedicle spinal instrumentation systems in the long term were evaluated. Results. Forty-four out of 467 screws failed (9%) in 16 patients, seven of whom were symptomatic. There were no plate failures. On comparing burst fractures with (n = 12) and without (n = 10) anterior column grafting, the latter group had a significant increase in implant failures, loss of sagittal alignment, and the time required to fusion. Overall, fusion occurred within 6.5 months. Conclusions. Anterior column reconstruction in anterior column-deficient spines will re-create the normal biomechanics and significantly reduce the incidence of implant failures and loss of sagittal alignment with these systems. Pedicle screw failure in itself is not necessarily associated with a bad result. These inexpensive, locally made unconventional systems, with the proper understanding of biomechanics and creation of appropriate load-sharing constructs, are as good as the conventional systems available today.
引用
收藏
页码:2150 / 2158
页数:9
相关论文
共 27 条
  • [11] Lorenz M.A., Zindrick M.R., Schwaegler P., A Comparison of single level fusions with and without hardware, Spine, 16, 8, (1991)
  • [12] Louis R., Fusion of the lumbar and sacral spine by internal fixation with screw plates, Clin Orthop, 203, pp. 18-33, (1986)
  • [13] Marchesi D.G., Thalgott J.S., Aebi M., Application and results of the AO internal fixation system in nontraumatic indications, Spine, 16, 3, (1991)
  • [14] McAfee P.C., Weiland D.J., Carlow J.J., Survivorship analysis of pedicle spinal instrumentation, Spine, 16, 8, (1991)
  • [15] McAfee P.C., Werner F.W., Glosson R.R., A biomechanical analysis of spinal instrumentation systems in thoracolumbar fractures comparison of traditional Harrington distraction instrumentation with segmental spinal instrumentation, Spine, 10, pp. 204-217, (1985)
  • [16] Ouahes M., Martini M., Results of the conservative treatment of 171 cases of Pott’s disease without neurologic involvement, Rev Chir Orthop, 74, pp. 563-568, (1988)
  • [17] Pun W.K., Chow S.P., Cheng C.L., Hsu L.C., Leong J.C., Tuberculosis of the lumbosacral junction. Long-term follow-up of 26 cases, J Bone Joint Surg [Br], 72, pp. 675-678, (1990)
  • [18] Rajasekaran S., Soundarapandian S., Progression of kyphosis in tuberculosis of the spine treated by anterior arthrodesis, J Bone Joint Surg [Am], 71, pp. 1314-1323, (1989)
  • [19] Rajasekaran S., Shanmugasundaram T.K., Prediction of the angle of gibbus deformity in tuberculosis of the spine, J Bone Joint Surg [Am], 69, pp. 503-509, (1987)
  • [20] Ranscon N.A., Larocca S.H., Thalgott J.S., Comparative Results of Three Posterolateral Lumbosacral Arthrodesis Techniques: No Instrumentation, Sublaminar Wiring, and AO In- Terpedicular Screw and Plate Fixation. Annual Meeting of the American Academy of Orthopaedic Surgeons, (1990)