ACS RX(TM) FLOW SUPPORT CATHETER AS A TEMPORARY STENT FOR DISSECTION OR OCCLUSION DURING BALLOON ANGIOPLASTY - INITIAL EXPERIENCE

被引:7
作者
HEUSER, RR [1 ]
MEHTA, S [1 ]
STRUMPF, RK [1 ]
机构
[1] HUMANA HOSP,CARDIOVASC CTR EXCELLENCE,PHOENIX,AZ
来源
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS | 1992年 / 27卷 / 01期
关键词
CORONARY ARTERY DISEASE; CORONARY ANGIOPLASTY; STENTS; COMPLICATIONS; DEVICES;
D O I
10.1002/ccd.1810270115
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The ACS RX(TM) flow support catheter, which functions as a temporary stent, was placed successfully during four procedures in three patients who had suboptimal results following angioplasty. This investigational device allowed prolonged perfusion and supported the vessel wall when coronary blood flow was compromised, avoiding emergent coronary artery bypass graft surgery during two procedures. In the remaining procedures the device was used as a bridge to surgery. These early applications of the flow support catheter following failed balloon angioplasty suggest a rapid, effective alternative to the autoperfusion balloon when it fails or is contraindicated because of the lesion location.
引用
收藏
页码:66 / 74
页数:9
相关论文
共 18 条
[1]   IN-HOSPITAL MORBIDITY AND MORTALITY IN PATIENTS UNDERGOING ELECTIVE CORONARY ANGIOPLASTY [J].
BREDLAU, CE ;
ROUBIN, GS ;
LEIMGRUBER, PP ;
DOUGLAS, JS ;
KING, SB ;
GRUENTZIG, AR .
CIRCULATION, 1985, 72 (05) :1044-1052
[2]   REGIONAL MYOCARDIAL BLOOD-FLOW WITH A REPERFUSION CATHETER AND AN AUTOPERFUSION BALLOON CATHETER DURING TOTAL CORONARY-OCCLUSION [J].
CHRISTENSEN, CW ;
LASSAR, TA ;
DALEY, LC ;
RIEDER, MA ;
SCHMIDT, DH .
AMERICAN HEART JOURNAL, 1990, 119 (02) :242-248
[3]   FLOW SUPPORT CATHETER FOR PROLONGED MAINTENANCE OF CORONARY BLOOD-FLOW [J].
CLUGSTON, R ;
OESTERLE, SN ;
MATTHEWS, R ;
DAWSON, R ;
GARRISON, M ;
ALKER, K ;
REEVES, T ;
VIRMANI, R ;
KLONER, RA .
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1991, 24 (04) :308-314
[4]  
DIDIER B P, 1991, Journal of the American College of Cardiology, V17, p302A
[5]   IN-HOSPITAL CARDIAC MORTALITY AFTER ACUTE CLOSURE AFTER CORONARY ANGIOPLASTY - ANALYSIS OF RISK-FACTORS FROM 8,207 PROCEDURES [J].
ELLIS, SG ;
ROUBIN, GS ;
KING, SB ;
DOUGLAS, JS ;
SHAW, RE ;
STERTZER, SH ;
MYLER, RK .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1988, 11 (02) :211-216
[6]  
FISCHMAN DL, 1991, CIRCULATION S2, V84, P588
[7]  
HEARN JA, 1991, CIRCULATION S2, V84, P589
[8]  
HERRMANN HC, 1991, CIRCULATION S2, V84, P590
[9]  
HOCHBERG MS, 1990, CIRCULATION, V82, P361
[10]   CLINICAL AND ANGIOGRAPHIC RESULTS OF BALLOON-EXPANDABLE INTRACORONARY STENTS IN RIGHT CORONARY-ARTERY STENOSES [J].
LEVINE, MJ ;
LEONARD, BM ;
BURKE, JA ;
NASH, ID ;
SAFIAN, RD ;
DIVER, DJ ;
BAIM, DS .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 16 (02) :332-339