X-RAY-DETECTION USING BULK GAAS

被引:18
作者
HOLLAND, AD [1 ]
SHORT, ADT [1 ]
CROSS, T [1 ]
机构
[1] EEV LTD, CHELMSFORD, ENGLAND
关键词
D O I
10.1016/0168-9002(94)90724-2
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Bulk GaAs has been investigated as a material for X-ray detection nominally in the 10-100 keV band using Schottky barrier detectors. The devices which were manufactured were investigated with respect to leakage current, charge collection efficiency and X-ray spectral resolution. A leakage current of 7 nA mm-2 at 20-degrees-C was measured and was not attributable to surface leakage. The X-ray charge collection efficiency was variable but was as high as 70%, due to defects in the bulk material and was a strong function of detector thickness and applied bias. The imperfect CCE results in degraded spectral resolution, however the work indicates that this type of detector can perform moderate spectroscopy for X-rays of energy > 14 keV, with a measured FWHM of 4.5 keV at 60 keV and 5.5 keV at 122 keV.
引用
收藏
页码:366 / 371
页数:6
相关论文
共 10 条
[1]   HIGH-PURITY LIQUID-PHASE EPITAXIAL GALLIUM-ARSENIDE NUCLEAR RADIATION DETECTOR [J].
ALEXIEV, D ;
BUTCHER, KSA .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 317 (1-2) :111-115
[2]  
BAUSER E, 1992, NUCL INSTRUM METH A, V322, P493
[3]   GAAS SOLID-STATE DETECTORS FOR PARTICLE PHYSICS [J].
BEAUMONT, SP ;
BERTIN, R ;
BOOTH, CN ;
BUTTAR, C ;
CARRARESI, L ;
CINDOLO, F ;
COLOCCI, M ;
COMBLEY, FH ;
DAURIA, S ;
DELPAPA, C ;
DOGRU, M ;
EDWARDS, M ;
FIORI, F ;
FOSTER, F ;
FRANCESCATO, A ;
HOU, Y ;
HOUSTON, P ;
JONES, B ;
LYNCH, JG ;
LISOWSKI, B ;
MATHESON, J ;
NAVA, F ;
NUTI, M ;
OSHEA, V ;
PELFER, PG ;
RAINE, C ;
SANTANA, J ;
SAUNDERS, I ;
SELLER, PH ;
SHARP, PH ;
SKILLIKORN, IO ;
SLOAN, T ;
SMITH, KM ;
TARTONI, N ;
TENHAVE, I ;
TURNBULL, RM ;
VINATTIERI, A ;
ZICHICHI, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 322 (03) :472-482
[4]  
BERWICK K, 1993, MATER RES SOC SYMP P, V302, P363, DOI 10.1557/PROC-302-363
[5]   EVALUATION OF EPITAXIAL N-GAAS FOR NUCLEAR RADIATION DETECTION [J].
EBERHARDT, JE ;
RYAN, RD ;
TAVENDALE, AJ .
NUCLEAR INSTRUMENTS & METHODS, 1971, 94 (03) :463-+
[6]   X-RAY FOCUSING USING SQUARE-PORE MICROCHANNEL PLATES - 1ST OBSERVATION OF CRUXIFORM IMAGE STRUCTURE [J].
FRASER, GW ;
BRUNTON, AN ;
LEES, JE ;
PEARSON, JF ;
FELLER, WB .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 324 (1-2) :404-407
[7]  
FRASER GW, 1993, HARD XRAY TELESCOPE
[8]   DEVELOPMENT OF BULK GAAS ROOM-TEMPERATURE RADIATION DETECTORS [J].
MCGREGOR, DS ;
KNOLL, GF ;
EISEN, Y ;
BRAKE, R .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1992, 39 (05) :1226-1236
[9]  
SZE SM, 1981, PHYSICS SEMICONDUCTO
[10]   IDENTIFICATION OF PARAMAGNETIC ASGA AND OPTICAL EL2 CENTERS IN SEMI-INSULATING GALLIUM-ARSENIDE [J].
WANG, GG ;
ZOU, YX .
JOURNAL OF APPLIED PHYSICS, 1988, 63 (08) :2595-2602