A HYBRID METHOD OF ATTENUATION CORRECTION FOR POSITRON EMISSION TOMOGRAPHY BRAIN STUDIES

被引:9
作者
BETTINARDI, V
GILARDI, MC
CARGNEL, S
RIZZO, G
TERAS, M
STRIANO, G
FAZIO, F
机构
[1] H CASTELFRANCO VENETO,DIV NUCL MED,TREVISO,ITALY
[2] UNIV TURKU,TURKU,FINLAND
来源
EUROPEAN JOURNAL OF NUCLEAR MEDICINE | 1994年 / 21卷 / 12期
关键词
POSITRON EMISSION TOMOGRAPHY; ATTENUATION CORRECTION; BRAIN;
D O I
10.1007/BF02426690
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A hybrid method for attenuation correction (HAC) in positron emission tomography (PET) brain studies is proposed, The technique requires the acquisition of two short (1 min) transmission scans immediately before or after the emission study, with the patient and the head fixation system in place and after removing the patient from the scanner with the head fixation system alone. The method combines a uniform map of attenuation coefficients for the patient's head with measured attenuation coefficients for the head fixation system to generate a hybrid attenuation map, The HAC method was calibrated on 30 PET cerebral studies for comparison with the conventional measured attenuation correction method by ROI analysis. Average differences of less than 3% were found for cortical and subcortical regions, The HAC technique is particularly suitable in a PET clinical environment, allowing a reduction of the total study time, greater comfort for patients and an increase in patient throughput.
引用
收藏
页码:1279 / 1284
页数:6
相关论文
共 21 条
[1]   DETERMINATION OF OBJECT CONTOUR FROM PROJECTIONS FOR ATTENUATION CORRECTION IN CRANIAL POSITRON EMISSION TOMOGRAPHY [J].
BERGSTROM, M ;
LITTON, J ;
ERIKSSON, L ;
BOHM, C ;
BLOMQVIST, G .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1982, 6 (02) :365-372
[2]   HEAD HOLDER FOR PET, CT, AND MR STUDIES [J].
BETTINARDI, V ;
SCARDAONI, R ;
GILARDI, MC ;
RIZZO, G ;
PERANI, D ;
PAULESU, E ;
STRIANO, G ;
TRIULZI, F ;
FAZIO, F .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1991, 15 (05) :886-892
[3]  
Carroll LR, 1983, EMISSION COMPUTED TO, P235
[4]  
CARSON RE, 1988, J NUCL MED, V29, P1558
[5]   PROBLEMS IN SIGNAL-TO-NOISE RATIO FOR ATTENUATION CORRECTION IN HIGH-RESOLUTION PET [J].
DAHLBOM, M ;
HOFFMAN, EJ .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1987, 34 (01) :288-293
[6]   POST-INJECTION TRANSMISSION ATTENUATION MEASUREMENTS FOR PET [J].
DAUBEWITHERSPOON, ME ;
CARSON, RE ;
GREEN, MV .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1988, 35 (01) :757-761
[7]  
HUANG SC, 1979, J COMPUT ASSIST TOMO, V3, P804
[8]  
HUANG SC, 1981, J NUCL MED, V22, P627
[9]   ORBITING TRANSMISSION SOURCE FOR POSITRON TOMOGRAPHY [J].
HUESMAN, RH ;
DERENZO, SE ;
CAHOON, JL ;
GEYER, AB ;
MOSES, WW ;
UBER, DC ;
VULETICH, T ;
BUDINGER, TF .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1988, 35 (01) :735-739
[10]   SCATTER SUPPRESSION BY USING A ROTATING PIN SOURCE IN PET TRANSMISSION MEASUREMENTS [J].
KUBLER, WK ;
OSTERTAG, H ;
HOVERATH, H ;
DOLL, J ;
ZIEGLER, S ;
LORENZ, WJ .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1988, 35 (01) :749-752