OPTIMIZATION OF LIQUID-CHROMATOGRAPHIC PARAMETERS FOR THE SEPARATION OF PRIORITY PHENOLS BY USING MIXED-LEVEL ORTHOGONAL ARRAY DESIGN

被引:25
作者
CHEE, KK [1 ]
LAN, WG [1 ]
WONG, MK [1 ]
LEE, HK [1 ]
机构
[1] NATL UNIV SINGAPORE,DEPT CHEM,SINGAPORE 0511,SINGAPORE
关键词
LIQUID CHROMATOGRAPHY; MIXED-LEVEL ORTHOGONAL ARRAY DESIGN; CHEMOMETRICS; SUBSTITUTED PHENOLS; PHENOLS;
D O I
10.1016/0003-2670(95)00214-K
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Mixed-level orthogonal array design (OAD) as a chemometric method has been employed to optimize liquid chromatographic (LC) conditions far the separation of environmental pollutants. Six parameters were examined by OAD, namely reversed-phase (C-18) LC columns from different manufacturers, content of methanol and acetonitrile in the mobile phase, initial time-duration of a fixed mobile phase composition, time-duration of a gradient elution programme, and mobile phase flow rate. The optimization of these parameters for the determination of eleven priority substituted phenols was carried out to demonstrate the applicability of mixed-level OAD in environmental analytical chemistry in which the use of trial-and-error procedures is often unsatisfactory due to sample complexity. The advantages and the disadvantages of mixed-level OAD were discussed.
引用
收藏
页码:271 / 280
页数:10
相关论文
共 45 条
[1]   TRACE DETERMINATION OF PHENOLIC-COMPOUNDS IN WATER BY REVERSED PHASE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION USING A CARBON-POLYETHYLENE TUBULAR ANODE [J].
ARMENTROUT, DN ;
MCLEAN, JD ;
LONG, MW .
ANALYTICAL CHEMISTRY, 1979, 51 (07) :1039-1045
[2]   PRINCIPLES OF HIGH-SPEED GAS CHROMATOGRAPHY WITH PACKED COLUMNS [J].
AYERS, BO ;
LOYD, RJ .
ANALYTICAL CHEMISTRY, 1961, 33 (08) :986-&
[3]   SIMPLEX OPTIMIZATION OF HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC SEPARATIONS [J].
BERRIDGE, JC .
JOURNAL OF CHROMATOGRAPHY, 1989, 485 :3-14
[4]   TAGUCHI DESIGN EXPERIMENTS FOR OPTIMIZING THE GAS-CHROMATOGRAPHIC ANALYSIS OF RESIDUAL SOLVENTS IN BULK PHARMACEUTICALS [J].
BILLOT, P ;
PITARD, B .
JOURNAL OF CHROMATOGRAPHY, 1992, 623 (02) :305-313
[5]   OPTIMIZATION OF THE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC SEPARATION OF STEROIDS BY THE OVERLAPPING RESOLUTION MAPPING PROCEDURE [J].
CHONG, KY ;
KHOO, TH ;
KOO, FS ;
ONG, CP ;
LI, SFY ;
LEE, HK ;
VENKATESH, B ;
TAN, CH .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1991, 14 (13) :2445-2455
[6]   COMPARISON OF OPTIMIZATION METHODS IN REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING MIXTURE DESIGNS AND MULTICRITERIA DECISION-MAKING [J].
COENEGRACHT, PMJ ;
SMILDE, AK ;
METTING, HJ ;
DOORNBOS, DA .
JOURNAL OF CHROMATOGRAPHY, 1989, 485 :195-217
[7]  
CORICA AC, 1994, J ASSOC OFF ANA CHEM, V77, P446
[8]   COMPUTER-ASSISTED OPTIMIZATION IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD DEVELOPMENT [J].
DEMING, SN ;
PALASOTA, JM ;
LEE, JG ;
SUN, LF .
JOURNAL OF CHROMATOGRAPHY, 1989, 485 :15-25
[9]   OPTIMUM CONDITIONS FOR SEPARATION IN GAS CHROMATOGRAPHY [J].
GIDDINGS, JC .
ANALYTICAL CHEMISTRY, 1960, 32 (12) :1707-1711
[10]   OPTIMIZATION OF SOLVENT STRENGTH AND SELECTIVITY FOR REVERSED-PHASE LIQUID-CHROMATOGRAPHY USING AN INTERACTIVE MIXTURE-DESIGN STATISTICAL TECHNIQUE [J].
GLAJCH, JL ;
KIRKLAND, JJ ;
SQUIRE, KM ;
MINOR, JM .
JOURNAL OF CHROMATOGRAPHY, 1980, 199 (OCT) :57-79