OPTIMIZATION OF LIQUID-CHROMATOGRAPHIC PARAMETERS FOR THE SEPARATION OF PRIORITY PHENOLS BY USING MIXED-LEVEL ORTHOGONAL ARRAY DESIGN

被引:25
作者
CHEE, KK [1 ]
LAN, WG [1 ]
WONG, MK [1 ]
LEE, HK [1 ]
机构
[1] NATL UNIV SINGAPORE,DEPT CHEM,SINGAPORE 0511,SINGAPORE
关键词
LIQUID CHROMATOGRAPHY; MIXED-LEVEL ORTHOGONAL ARRAY DESIGN; CHEMOMETRICS; SUBSTITUTED PHENOLS; PHENOLS;
D O I
10.1016/0003-2670(95)00214-K
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Mixed-level orthogonal array design (OAD) as a chemometric method has been employed to optimize liquid chromatographic (LC) conditions far the separation of environmental pollutants. Six parameters were examined by OAD, namely reversed-phase (C-18) LC columns from different manufacturers, content of methanol and acetonitrile in the mobile phase, initial time-duration of a fixed mobile phase composition, time-duration of a gradient elution programme, and mobile phase flow rate. The optimization of these parameters for the determination of eleven priority substituted phenols was carried out to demonstrate the applicability of mixed-level OAD in environmental analytical chemistry in which the use of trial-and-error procedures is often unsatisfactory due to sample complexity. The advantages and the disadvantages of mixed-level OAD were discussed.
引用
收藏
页码:271 / 280
页数:10
相关论文
共 45 条
[11]   UNIFORM SHELL DESIGNS FOR OPTIMIZATION IN REVERSED-PHASE LIQUID-CHROMATOGRAPHY [J].
HU, YZ ;
MASSART, DL .
JOURNAL OF CHROMATOGRAPHY, 1989, 485 :311-323
[12]  
HUSSAIN S, 1965, J CHROMATOGR, V18, P419
[13]   OPTIMIZATION PROCEDURE FOR THE SILANIZATION OF SILICAS FOR REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY .1. ELIMINATION OF NONSIGNIFICANT VARIABLES [J].
JONES, K .
JOURNAL OF CHROMATOGRAPHY, 1987, 392 :1-10
[14]  
JONES K, 1987, J CHROMATOGR, V392, P7
[15]   PRIORITY POLLUTANTS I-A PERSPECTIVE VIEW [J].
KEITH, LH ;
TELLIARD, WA .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1979, 13 (04) :416-423
[16]   OPTIMIZATION OF THE ISOCRATIC HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC SEPARATION OF SELECTED PHTHALATES USING THE OVERLAPPING RESOLUTION MAPPING TECHNIQUE [J].
KHAN, MR ;
ONG, CP ;
LI, SFY ;
LEE, HK .
JOURNAL OF CHROMATOGRAPHY, 1990, 513 :360-366
[17]   ULTRA-TRACE ANALYSIS OF PHENOLS IN WATER USING HIGHPERFORMANCE LIQUID-CHROMATOGRAPHY WITH ONLINE REACTION DETECTION [J].
LAMPRECHT, G ;
HUBER, JFK .
JOURNAL OF CHROMATOGRAPHY A, 1994, 667 (1-2) :47-57
[18]  
LAN WG, 1994, ANALYST, V119, P1669, DOI 10.1039/an9941901669
[19]   4-LEVEL ORTHOGONAL ARRAY DESIGN AS A CHEMOMETRIC APPROACH TO THE OPTIMIZATION OF POLAROGRAPHIC REACTION SYSTEM FOR PHOSPHORUS DETERMINATION [J].
LAN, WG ;
WONG, MK ;
NI, C ;
SIN, YM .
TALANTA, 1994, 41 (11) :1917-1927
[20]   ORTHOGONAL ARRAY DESIGN AS A CHEMOMETRIC METHOD FOR THE OPTIMIZATION OF ANALYTICAL PROCEDURES .4. MIXED-LEVEL DESIGN AND ITS APPLICATION TO THE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF POLYCYCLIC AROMATIC-HYDROCARBONS [J].
LAN, WG ;
CHEE, KK ;
WONG, MK ;
LEE, HK ;
SIN, YM .
ANALYST, 1995, 120 (02) :281-287