ANALYSIS OF PESTICIDE-RESIDUES IN FOOD USING GAS-CHROMATOGRAPHY TANDEM MASS-SPECTROMETRY WITH A BENCHTOP ION-TRAP MASS-SPECTROMETER

被引:42
作者
SCHACHTERLE, S [1 ]
BRITTAIN, RD [1 ]
MILLS, JD [1 ]
机构
[1] VARIAN ASSOCIATES INC,WALTON KT12 2QF,SURREY,ENGLAND
关键词
D O I
10.1016/S0021-9673(94)89115-X
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Recent developments on the Saturn GC-MS system offer enhanced capabilities for both the ion isolation and collision-induced dissociation steps in GC-MS-MS. With these improvements, benchtop GC-MS-MS can improve the detection limit of mass spectrometers for low-level target compounds in complex matrices. With this brief study of malathion, we demonstrate (I) excellent sensitivity, (2) wide dynamic range and (3) effective elimination of chemical background. GC-MS-MS is compared to standard GC-EI-MS and GC-CI-MS techniques for the analysis of malathion in orange extract. GC-MS-MS is the most selective and sensitive technique, virtually eliminating the background interference. Product ion mass spectra are invariant across the chromatographic peak and excellent linearity is observed over a range from 2.2 pg/mu l to 2.2 ng/mu l for malathion. Detection limit by GC-MS-MS was estimated at 0.5 mu g/kg in the orange oil matrix (S/N = 5).
引用
收藏
页码:185 / 193
页数:9
相关论文
共 12 条
[1]  
BOLTON B, 1993, 41ST ASMS C MASS SPE, pA474
[2]   TANDEM MASS-SPECTROMETRY FOR TRACE ANALYSIS [J].
JOHNSON, JV ;
YOST, RA .
ANALYTICAL CHEMISTRY, 1985, 57 (07) :A758-&
[3]   TANDEM-IN-SPACE AND TANDEM-IN-TIME MASS-SPECTROMETRY - TRIPLE QUADRUPOLES AND QUADRUPOLE ION TRAPS [J].
JOHNSON, JV ;
YOST, RA ;
KELLEY, PE ;
BRADFORD, DC .
ANALYTICAL CHEMISTRY, 1990, 62 (20) :2162-2172
[4]   BROAD-BAND EXCITATION IN THE QUADRUPOLE ION-TRAP MASS-SPECTROMETER USING SHAPED PULSES CREATED WITH THE INVERSE FOURIER-TRANSFORM [J].
JULIAN, RK ;
COOKS, RG .
ANALYTICAL CHEMISTRY, 1993, 65 (14) :1827-1833
[5]   INSTRUMENTATION, APPLICATIONS, AND ENERGY DEPOSITION IN QUADRUPOLE ION-TRAP TANDEM MASS-SPECTROMETRY [J].
LOURIS, JN ;
COOKS, RG ;
SYKA, JEP ;
KELLEY, PE ;
STAFFORD, GC ;
TODD, JFJ .
ANALYTICAL CHEMISTRY, 1987, 59 (13) :1677-1685
[6]   ION TRAP MASS-SPECTROMETRY [J].
MARCH, RE .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1992, 118 :71-135
[7]   COLLISIONAL ACTIVATION WITH RANDOM NOISE IN ION TRAP MASS-SPECTROMETRY [J].
MCLUCKEY, SA ;
GOERINGER, DE ;
GLISH, GL .
ANALYTICAL CHEMISTRY, 1992, 64 (13) :1455-1460
[8]   THE USE OF DYNAMICALLY PROGRAMMED SCANS TO GENERATE PARENT-ION TANDEM MASS-SPECTRA WITH THE ION-TRAP MASS-SPECTROMETER [J].
TODD, JFJ ;
PENMAN, AD ;
THORNER, DA ;
SMITH, RD .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1990, 4 (04) :108-113
[9]   ION TRAP MASS-SPECTROMETER - PAST, PRESENT, AND FUTURE [J].
TODD, JFJ .
MASS SPECTROMETRY REVIEWS, 1991, 10 (01) :3-52
[10]   GAS-CHROMATOGRAPHY TANDEM MASS-SPECTROMETRY IMPLEMENTED ON A BENCH-TOP QUADRUPOLE ION TRAP-BASED INSTRUMENT USING RANDOM NOISE TO EFFECT COLLISION-INDUCED DISSOCIATION [J].
VANBERKEL, GJ ;
GOERINGER, DE .
ANALYTICA CHIMICA ACTA, 1993, 277 (01) :41-54