Quantitation of articular cartilage using magnetic resonance imaging and three-dimensional reconstruction

被引:59
作者
Marshall, KW
Mikulis, DJ
Guthrie, BM
机构
[1] TORONTO HOSP, DEPT RADIOL, TORONTO, ON M5T 2S8, CANADA
[2] UNIV TORONTO, DEPT COMMUNITY HLTH, TORONTO, ON, CANADA
关键词
D O I
10.1002/jor.1100130603
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
A quadrature knee coil was used in conjunction with a magnetic resonance imaging scanner for quantitation of test phantom volumes, ex vivo bovine cartilage thickness, and in vivo human articular cartilage volumes. Optimal magnetic resonance parameters were obtained by testing a series of spin-echo and gradient-echo pulse sequences to determine the sequence that provided the highest resolution of articular cartilage and best defined the cartilage interfaces with synovial fluid and subchondral bone. Extensive testing revealed that two sequences were required to define articular cartilage accurately: a spoiled gradient-echo sequence and a steady state free-precession sequence. Three-dimensional reconstruction and statistical analyses of test phantoms and of bovine and human cartilage images were performed. Differences between actual phantom volumes and three-dimensional measurements demonstrated that, as magnetic resonance slice thickness was increased, the measurement variability also increased (coefficient of variation ranging from 1.7 +/- 1.3% for 1.0 mm slice thickness to 22.7 +/- 1.9% for 3.0 mm slice thickness). When the phantom volume was greater than 1,800 mm(3), the intraobserver, interobserver and interscan accuracies were greater than 97, 98, and 96%, respectively. This high degree of reproducibility pertained for the data on in vivo human cartilage data also. For experienced observers, the intraobserver and interobserver reproducibility were greater than 98 and 97%, respectively. The interscan reproducibility was greater than 98%. These data demonstrate that improved magnetic resonance pulse sequencing, in conjunction with three-dimensional reconstruction and measurement techniques, can accurately and reproducibly measure the volume of articular cartilage. Clinical application of this approach offers the potential for early diagnosis BE osteoarthritis and for serial, noninvasive assessment of changes in articular cartilage volume in response to therapeutic modalities.
引用
收藏
页码:814 / 823
页数:10
相关论文
共 42 条
  • [21] ARTICULAR-CARTILAGE DEFECTS OF THE KNEE - CORRELATION BETWEEN MAGNETIC-RESONANCE-IMAGING AND GROSS PATHOLOGY
    KARVONEN, RL
    NEGENDANK, WG
    FRASER, SM
    MAYES, MD
    AN, T
    FERNANDEZMADRID, F
    [J]. ANNALS OF THE RHEUMATIC DISEASES, 1990, 49 (09) : 672 - 675
  • [22] KONIG H, 1987, RADIOLOGY, V164, P753
  • [23] STRUCTURE, FUNCTION, AND DEGENERATION OF BOVINE HYALINE CARTILAGE - ASSESSMENT WITH MR IMAGING INVITRO
    LEHNER, KB
    RECHL, HP
    GMEINWIESER, JK
    HEUCK, AF
    LUKAS, HP
    KOHL, HP
    [J]. RADIOLOGY, 1989, 170 (02) : 495 - 499
  • [24] DETECTION OF ARTICULAR DEFECTS USING MAGNETIC-RESONANCE-IMAGING - AN EXPERIMENTAL-STUDY
    MAH, ET
    LANGLOIS, SLP
    LOTT, CW
    LEE, WKC
    BROWN, G
    [J]. AUSTRALIAN AND NEW ZEALAND JOURNAL OF SURGERY, 1990, 60 (12): : 977 - 981
  • [25] MARTEL W, 1991, J RHEUMATOL, V18, P32
  • [26] CHONDROMALACIA PATELLAE - DIAGNOSIS WITH MR IMAGING
    MCCAULEY, TR
    KIER, R
    LYNCH, KJ
    JOKL, P
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1992, 158 (01) : 101 - 105
  • [27] EXPERIMENTAL-MODEL OF OSTEOARTHRITIS - EARLY MORPHOLOGICAL AND BIOCHEMICAL CHANGES
    MCDEVITT, C
    GILBERTSON, E
    MUIR, H
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1977, 59 (01): : 24 - 35
  • [28] MOW VC, 1990, BRIS MYER Z, P1
  • [29] MAGNETIC-RESONANCE-IMAGING OF THE RABBIT KNEE - DETECTION OF CARTILAGE PROTEOGLYCAN DEGRADATION
    OBYRNE, EM
    PAUL, PK
    BLANCUZZI, V
    WILSON, D
    GUNSON, D
    WANG, JZ
    MEZRICH, RS
    DOUGLAS, FL
    [J]. AGENTS AND ACTIONS, 1991, 34 (1-2): : 214 - 216
  • [30] PAUL P K, 1990, Arthritis and Rheumatism, V33, pS91