QUANTIFICATION OF LEFT-TO-RIGHT ATRIAL SHUNTS WITH VELOCITY-ENCODED CINE NUCLEAR-MAGNETIC-RESONANCE IMAGING

被引:107
作者
BRENNER, LD
CAPUTO, GR
MOSTBECK, G
STEIMAN, D
DULCE, M
CHEITLIN, MD
OSULLIVAN, M
HIGGINS, CB
机构
[1] UNIV CALIF SAN FRANCISCO, DEPT RADIOL, BOX 0628, SAN FRANCISCO, CA 94143 USA
[2] UNIV CALIF SAN FRANCISCO, MED CTR, DEPT RADIOL, SAN FRANCISCO, CA 94143 USA
[3] UNIV CALIF SAN FRANCISCO, MED CTR, DEPT MED, SAN FRANCISCO, CA 94143 USA
关键词
D O I
10.1016/0735-1097(92)90384-Y
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. The purpose of this study was to evaluate the ability of velocity-encoded nuclear magnetic resonance (NMR) imaging to quantify left to right intracardiac shunts in patients with an atrial septal defect. Background. Quantification of intracardiac shunts is clinically important in planning therapy. Methods. Velocity-encoded NMR imaging was used to quantify stroke flow in the aorta and in the main pulmonary artery in a group of patients who were known to have an increased pulmonary to systemic flow ratio (Q(p)/Q(s)). The velocity-encoded NMR flow data were used to calculate Q(p)/Q(s), and these values were compared with measurements of Q(p)/Q(s) obtained with oximetric data derived from cardiac catheterization and from stroke volume measurements of the two ventricles by using volumetric data from biphasic spin echo and cine NMR images obtained at end-diastole and end-systole. Results. Two independent observers measured Q(p)/Q(s) by using velocity-encoded NMR imaging in 11 patients and found Q(p)/Q(s) ranging from 1.4:1 to 3.9:1. These measurements correlated well with both oximetric data (r = 0.91, SEE = 0.35) and ventricular volumetric data (r = 0.94, SEE = 0.30). Interobserver reproducibility for Q(p)/Q(s) by velocity-encoded NMR imaging was good (r = 0.97, SEE = 0.20). Conclusions. Velocity-encoded NMR imaging is an accurate and reproducible method for measuring Q(p)/Q(s) in left to right shunts. Because it is completely noninvasive, it can be used to monitor shunt volume over time.
引用
收藏
页码:1246 / 1250
页数:5
相关论文
共 23 条
[1]   QUANTITATION OF ANTEGRADE AND RETROGRADE BLOOD-FLOW IN THE HUMAN AORTA BY MAGNETIC-RESONANCE VELOCITY MAPPING [J].
BOGREN, HG ;
KLIPSTEIN, RH ;
FIRMIN, DN ;
MOHIADDIN, RH ;
UNDERWOOD, SR ;
REES, RSO ;
LONGMORE, DB .
AMERICAN HEART JOURNAL, 1989, 117 (06) :1214-1222
[2]   DETERMINATION OF LEFT-VENTRICULAR VOLUME AND MASS WITH USE OF BIPHASIC SPIN-ECHO MR IMAGING - COMPARISON WITH CINE MR [J].
CAPUTO, GR ;
SUZUKI, JI ;
KONDO, C ;
CHO, H ;
QUAIFE, RA ;
HIGGINS, CB ;
PARKER, DL .
RADIOLOGY, 1990, 177 (03) :773-777
[3]   RIGHT AND LEFT LUNG PERFUSION - INVITRO AND INVIVO VALIDATION WITH OBLIQUE-ANGLE, VELOCITY-ENCODED CINE MR IMAGING [J].
CAPUTO, GR ;
KONDO, C ;
MASUI, T ;
GERACI, SJ ;
FOSTER, E ;
OSULLIVAN, MM ;
HIGGINS, CB .
RADIOLOGY, 1991, 180 (03) :693-698
[4]  
ELLIOTT M, 1980, AM J CARDIOL, V46, P265
[5]   EVALUATION OF PULMONARY AND SYSTEMIC BLOOD-FLOW BY TWO-DIMENSIONAL DOPPLER ECHOCARDIOGRAPHY USING FAST FOURIER-TRANSFORM SPECTRAL-ANALYSIS [J].
GOLDBERG, SJ ;
SAHN, DJ ;
ALLEN, HD ;
VALDESCRUZ, LM ;
HOENECKE, H ;
CARNAHAN, Y .
AMERICAN JOURNAL OF CARDIOLOGY, 1982, 50 (06) :1394-1400
[6]  
GREENFIELD L D, 1975, Critical Reviews in Clinical Radiology and Nuclear Medicine, V6, P217
[7]  
GROSSMAN W, 1986, CARDIAC CATHETERIZAT, P156
[8]   NON-INVASIVE EVALUATION OF THE RATIO OF PULMONARY TO SYSTEMIC FLOW IN ATRIAL SEPTAL-DEFECT BY DUPLEX DOPPLER ECHOCARDIOGRAPHY [J].
KITABATAKE, A ;
INOUE, M ;
ASAO, M ;
ITO, H ;
MASUYAMA, T ;
TANOUCHI, J ;
MORITA, T ;
HORI, M ;
YOSHIMA, H ;
OHNISHI, K ;
ABE, H .
CIRCULATION, 1984, 69 (01) :73-79
[9]   RIGHT AND LEFT-VENTRICULAR STROKE VOLUME MEASUREMENTS WITH VELOCITY-ENCODED CINE MR IMAGING - INVITRO AND INVIVO VALIDATION [J].
KONDO, C ;
CAPUTO, GR ;
SEMELKA, R ;
FOSTER, E ;
SHIMAKAWA, A ;
HIGGINS, CB .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 157 (01) :9-16
[10]  
LONGMORE DB, 1985, LANCET, V1, P1360