POLYMERIC MEMBRANES AND COUPLED ENZYMES IN THE DESIGN OF BIOSENSORS

被引:12
作者
COULET, PR
机构
[1] Laboratoire de Génie Enzymatique, UMR 106 CNRS, Université Claude Bernard, Lyon 1, 69622 Villuerbanne Cédex, 43 Bd du
关键词
BIOSENSORS; IMMOBILIZED ENZYMES; LUMINESCENCE; MICROELECTRONICS;
D O I
10.1016/0376-7388(92)85023-C
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Biosensors are new analytical tools associating a biologically active sensing membrane with a specific transducer which can be electrochemical, thermal, optical or based on mass variation. Sensing corresponds to the selective molecular recognition, generally by enzymes or antibodies, of a target analyte followed by the occurrence of a physico-chemical signal converted by the transducer into an electrical signal. This signal can be correlated to the concentration of the target analyte. Two main roles can be attributed to the membrane: it enables the immobilization or confinement of the bioactive material capable of molecular recognition in the immediate vicinity of the transducer tip and ensures additional selectivity to the system. The role of the membranes is described for enzyme electrodes which are the first operational biosensors now in use. Some useful immobilization procedures and design of anti-interference multilayer membranes are detailed. Extension of the role of membranes to optical systems is exemplified with fiber-optic biosensors based on fluorescence or luminescence. Finally a coating procedure with ultrathin layers of microsensors is presented showing promise for the development of bioelectronics in the near future.
引用
收藏
页码:217 / 228
页数:12
相关论文
共 33 条
[21]  
PICHON GJ, 1968, Patent No. 1596789
[22]  
PICHON GJ, 1968, Patent No. 1596790
[23]  
ROMETTE JL, 1987, GBF MONOGRAPHS, V10, P81
[24]   GLUCOSE-ELIMINATING ENZYME ELECTRODE FOR DIRECT SUCROSE DETERMINATION IN GLUCOSE-CONTAINING SAMPLES [J].
SCHELLER, F ;
RENNEBERG, R .
ANALYTICA CHIMICA ACTA, 1983, 152 (SEP) :265-269
[25]   BIOSENSORS - TRENDS AND COMMERCIALIZATION [J].
SCHELLER, FW ;
SCHUBERT, F ;
RENNEBERG, R ;
MULLER, HG ;
JANCHEN, M ;
WEISE, H .
BIOSENSORS, 1985, 1 (02) :135-160
[26]   A FIBER OPTIC BIOSENSOR BASED ON FLUOROMETRIC DETECTION USING CONFINED MACROMOLECULAR NICOTINAMIDE ADENINE-DINUCLEOTIDE DERIVATIVES [J].
SCHEPER, T ;
BUCKMANN, AF .
BIOSENSORS & BIOELECTRONICS, 1990, 5 (02) :125-135
[27]   AFFINITY SENSOR - A NEW TECHNIQUE FOR DEVELOPING IMPLANTABLE SENSORS FOR GLUCOSE AND OTHER METABOLITES [J].
SCHULTZ, JS ;
MANSOURI, S ;
GOLDSTEIN, IJ .
DIABETES CARE, 1982, 5 (03) :245-253
[28]   STATUS OF MONITORING IN BIOTECHNOLOGY [J].
SCHULTZ, JS ;
MEYERHOFF, M .
ENZYME AND MICROBIAL TECHNOLOGY, 1987, 9 (11) :697-699
[29]   CHEMICAL SENSORS BASED ON IMMOBILIZED INDICATORS AND FIBER OPTICS [J].
SEITZ, WR .
CRC CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 1988, 19 (02) :135-173
[30]   ENZYME COLLAGEN MEMBRANE FOR ELECTROCHEMICAL DETERMINATION OF GLUCOSE [J].
THEVENOT, DR ;
STERNBERG, R ;
COULET, PR ;
LAURENT, J ;
GAUTHERON, DC .
ANALYTICAL CHEMISTRY, 1979, 51 (01) :96-100