HEPATIC CONTRAST ENHANCEMENT AT CT - INFLUENCE OF INTRAVENOUS GLUCAGON IN A CANINE MODEL

被引:3
作者
WARSHAUER, DM [1 ]
HIKEN, JN [1 ]
MOLINA, PL [1 ]
HACKNEY, SL [1 ]
BELLINGER, DA [1 ]
LEE, JKT [1 ]
机构
[1] UNIV N CAROLINA, SCH MED, DEPT LAB & ANIM MED, CHAPEL HILL, NC 27599 USA
关键词
COMPUTED TOMOGRAPHY (CT); CONTRAST MEDIA; DRUGS; EFFECTS; GLUCAGON; LIVER; CT;
D O I
10.1148/radiology.197.2.7480678
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To investigate the effect of glucagon on the timing and degree of hepatic enhancement at computed tomography. MATERIALS AND METHODS: Each of 11 dogs underwent injection of contrast material at two uniphasic rates (0.5 mL/sec and 1.5 mL/sec) with and without previous intravenous administation of 0.5 mg of glucagon. Scans were obtained at a single intrahepatic level every 3.5 seconds for 120-160 seconds. Attenuation values in the liver, aorta, portal vein, and inferior vena cava (IVC) were measured. RESULTS: Glucagon administration was associated with greater hepatic enhancement throughout the study: Peak hepatic enhancement was greater at contrast injection rates of 0.5 mL/sec (P = .021) and 1.5 mL/sec (P = .0001). Peak hepatic enhancement also occurred earlier during the glucagon runs. Portal vein enhancement was greater during the glucagon runs at an injection rate of 1.5 mL/sec (P = .032). IVC enhancement was greater during the nonglucagon runs at 0.5 mL/sec (P = .013) and at 1.5 mL/sec (P = .005). CONCLUSION: Intravenous administration of glucagon before contrast material injection produces greater and more rapid hepatic enhancement in a canine model.
引用
收藏
页码:365 / 368
页数:4
相关论文
共 27 条
[1]   UNDERSTANDING AND OPTIMIZING USE OF CONTRAST MATERIAL FOR CT OF THE LIVER [J].
BARON, RL .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (02) :323-331
[2]   EFFECT OF CONTRAST CONCENTRATION ON ABDOMINAL ENHANCEMENT IN THE RABBIT - SPIRAL COMPUTED-TOMOGRAPHY EVALUATION [J].
BLUEMKE, DA ;
FISHMAN, EK ;
ANDERSON, JH .
ACADEMIC RADIOLOGY, 1995, 2 (03) :226-231
[3]  
BOND JH, 1979, J LAB CLIN MED, V93, P594
[4]   COST-EFFECTIVE USE OF LOW-OSMOLALITY CONTRAST-MEDIA FOR CT OF THE LIVER - EVALUATION OF LIVER ENHANCEMENT PROVIDED BY VARIOUS DOSES OF IOHEXOL [J].
BREE, RL ;
PARISKY, YR ;
BERNARDINO, ME ;
COSTELLO, P ;
LEDER, R ;
BROWN, PC .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (03) :579-583
[5]   MR MEASUREMENTS OF MESENTERIC VENOUS FLOW - PROSPECTIVE EVALUATION IN HEALTHY-VOLUNTEERS AND PATIENTS WITH SUSPECTED CHRONIC MESENTERIC ISCHEMIA [J].
BURKART, DJ ;
JOHNSON, CD ;
READING, CC ;
EHMAN, RL .
RADIOLOGY, 1995, 194 (03) :801-806
[6]  
BURNS GP, 1969, ARCH SURG-CHICAGO, V98, P790
[7]   HEPATIC CT ENHANCEMENT .1. ALTERATIONS IN THE VOLUME OF CONTRAST MATERIAL WITHIN THE SAME PATIENTS [J].
CHAMBERS, TP ;
BARON, RL ;
LUSH, RM .
RADIOLOGY, 1994, 193 (02) :513-517
[8]   HEPATIC CT ENHANCEMENT - A METHOD TO DEMONSTRATE REPRODUCIBILITY [J].
CHAMBERS, TP ;
BARON, RL ;
LUSH, RM ;
DODD, GD ;
MILLER, WJ ;
CONFER, SR .
RADIOLOGY, 1993, 188 (03) :627-631
[9]   GLUCAGON - COMMON UNTOWARD REACTIONS - REVIEW AND RECOMMENDATIONS [J].
CHERNISH, SM ;
MAGLINTE, DDT .
RADIOLOGY, 1990, 177 (01) :145-146
[10]  
CHOU CC, 1983, FED PROC, V42, P1658