OPTIMIZED SEPARATION OF 7 CORTICOSTEROIDS BY MICELLAR ELECTROKINETIC CHROMATOGRAPHY

被引:38
作者
JUMPPANEN, JH
WIEDMER, SK
SIREN, H
RIEKKOLA, ML
HAARIO, H
机构
[1] UNIV HELSINKI,DEPT CHEM,DIV ANALYT CHEM,SF-00014 HELSINKI,FINLAND
[2] UNIV HELSINKI,DEPT MATH,SF-00100 HELSINKI,FINLAND
关键词
D O I
10.1002/elps.11501501191
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The corticosteroids studied can be effectively separated by employing micellar electrokinetic capillary chromatography (MECC). The effect of pH, berate concentration and the sodium dodecyl sulfate (SDS) concentration on both the resolution and the selectivity was studied under 15 different experimental conditions. The experimental design was similar to the central composite design approach. Empirical quadratic regression models were derived for analyte migration time, band broadening and analyte velocity. Satisfactory regression fits and coefficients of determination for prediction were obtained with cross-validated models. The models for analyte migration time and analyte velocity were in good agreement with theory. Modeling of the band broadening seemed to be somewhat more complicated. Optimum conditions for resolution and selectivity were different. This is due to the fact that selectivity studies ignore the electroosmotic and band broadening properties of different electrolyte solutions. However, the study of the selectivity yielded good information about the suitability of the electrolyte systems for the particular separation problem. Although a high solubilizing power of SDS caused the corticosteroids to partition strongly into the SDS micelles, a good separation could be achieved at low SDS concentrations.
引用
收藏
页码:1267 / 1272
页数:6
相关论文
共 16 条
  • [1] DETERMINATION OF URINARY 18-HYDROXYCORTISOL BY ISOCRATIC NORMAL-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    CHIBA, H
    ITO, Y
    MATSUNO, K
    KOBAYASHI, K
    KUROSAWA, T
    IKEGAWA, S
    MAHARA, R
    TOHMA, M
    [J]. JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1993, 613 (01): : 132 - 136
  • [2] CRAPO L, 1979, METABOLISM, V28, P147
  • [3] MULTIPLE-CRITERIA OPTIMIZATION
    DEMING, SN
    [J]. JOURNAL OF CHROMATOGRAPHY, 1991, 550 (1-2): : 15 - 25
  • [4] DRAPER NR, 1976, APPLIED REGRESSION A
  • [5] OPTIMIZATION OF MICELLAR ELECTROKINETIC CHROMATOGRAPHY
    FOLEY, JP
    [J]. ANALYTICAL CHEMISTRY, 1990, 62 (13) : 1302 - 1308
  • [6] OPTIMIZATION OF PRECISION AND THROUGHPUT IN MICELLAR ELECTROKINETIC CHROMATOGRAPHY
    HAYASHI, Y
    MATSUDA, R
    TERABE, S
    [J]. CHROMATOGRAPHIA, 1993, 37 (3-4) : 149 - 155
  • [7] DETERMINATION OF CORTICOSTEROIDS IN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AFTER PRECOLUMN DERIVATIZATION WITH 2-(4-CARBOXYPHENYL)-5,6-DIMETHYLBENZIMIDAZOLE
    KATAYAMA, M
    MASUDA, Y
    TANIGUCHI, H
    [J]. JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1993, 612 (01): : 33 - 39
  • [8] SEPARATION AND DETERMINATION OF LIPOPHILIC CORTICOSTEROIDS AND BENZOTHIAZEPIN ANALOGS BY MICELLAR ELECTROKINETIC CHROMATOGRAPHY USING BILE-SALTS
    NISHI, H
    FUKUYAMA, T
    MATSUO, M
    TERABE, S
    [J]. JOURNAL OF CHROMATOGRAPHY, 1990, 513 : 279 - 295
  • [9] SEPARATION OF CORTICOSTEROIDS AND AROMATIC-HYDROCARBONS BY CYCLODEXTRIN-MODIFIED MICELLAR ELECTROKINETIC CHROMATOGRAPHY
    NISHI, H
    MATSUO, M
    [J]. JOURNAL OF LIQUID CHROMATOGRAPHY, 1991, 14 (05): : 973 - 986
  • [10] DIRECT RADIOIMMUNOASSAY OF PLASMA CORTISOL
    ROLLERI, E
    ZANNINO, M
    ORLANDINI, S
    MALVANO, R
    [J]. CLINICA CHIMICA ACTA, 1976, 66 (03) : 319 - 330