INTEGRATED IMPLANTABLE DEVICE FOR LONG-TERM GLUCOSE MONITORING

被引:50
作者
WILKINS, E [1 ]
ATANASOV, P [1 ]
MUGGENBURG, BA [1 ]
机构
[1] INHALAT TOXICOL RES INST, ALBUQUERQUE, NM 87185 USA
关键词
GLUCOSE BIOSENSOR; TELEMETRY; CONTINUOUS GLUCOSE MONITORING;
D O I
10.1016/0956-5663(95)96894-5
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
In this study we report the development of an integrated implantable device for glucose monitoring. The dimensions of the device (5.0 x 7.0 x 1.5 cm) allow implantation under the abdominal skin of a large animal for in vivo evaluation of sensor performance. The experimental set-up includes amperometric glucose biosensor, a miniature potentiostat, an FM signal transmitter, a power supply and an antenna and receiver linked to a computer-based data acquisition system. The device performance was evaluated in vitro using a ten-day continuous test and other long-term operation experiments. The biosensor was tested in different model solutions that simulated the physiological environment in which it will be ultimately used. A linear response to glucose concentration was obtained up to 25 mM glucose, with a sensitivity of less than 0.5 mu A/mM. The ability of the biosensor to measure glucose levels in serum was also tested, and a good correlation demonstrated between glucose serum levels measured by routine technique and those measured using the biosensor (R(2) = 0.993; slope = 0.996). Initial results obtained from the short-term subcutaneous implantation of the sensor demonstrate its potential for the monitoring of glucose concentration in vivo.
引用
收藏
页码:485 / 494
页数:10
相关论文
共 25 条
[1]  
ABEL P, 1984, BIOMED BIOCHIM ACTA, V43, P577
[2]   BIOSENSOR FOR CONTINUOUS GLUCOSE MONITORING [J].
ATANASOV, P ;
WILKINS, E .
BIOTECHNOLOGY AND BIOENGINEERING, 1994, 43 (03) :262-266
[3]  
Buchwald H, 1992, ASAIO J, V38, P772, DOI 10.1097/00002480-199210000-00005
[4]   ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY [J].
CLARK, LC ;
LYONS, C .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1962, 102 (01) :29-&
[5]   IMPLANTED ELECTROENZYMATIC GLUCOSE SENSORS [J].
CLARK, LC ;
DUGGAN, CA .
DIABETES CARE, 1982, 5 (03) :174-180
[6]   DESIGN AND RESPONSE CHARACTERISTICS OF AN ENZYME ELECTRODE FOR MEASUREMENT OF PENICILLIN IN FERMENTATION BROTH [J].
ENFORS, SO ;
NILSSON, H .
ENZYME AND MICROBIAL TECHNOLOGY, 1979, 1 (04) :260-264
[7]   DEVELOPMENT OF AN IMPLANTABLE ELECTROCATALYTIC GLUCOSE SENSOR [J].
GEBHARDT, U ;
LUFT, G ;
RICHTER, GJ ;
STURM, FV .
BIOELECTROCHEMISTRY AND BIOENERGETICS, 1978, 5 (04) :607-624
[8]   ENZYME ELECTRODES [J].
GOUGH, DA ;
ANDRADE, JD .
SCIENCE, 1973, 180 (4084) :380-384
[9]   ENZYME ELECTRODE FOR AMPEROMETRIC DETERMINATION OF GLUCOSE [J].
GUILBAULT, GG ;
LUBRANO, GJ .
ANALYTICA CHIMICA ACTA, 1973, 64 (03) :439-455
[10]   TOWARDS CONTINUOUS GLUCOSE MONITORING - INVIVO EVALUATION OF A MINIATURIZED GLUCOSE SENSOR IMPLANTED FOR SEVERAL DAYS IN RAT SUBCUTANEOUS TISSUE [J].
MOATTISIRAT, D ;
CAPRON, E ;
POITOUT, V ;
REACH, G ;
BINDRA, DS ;
ZHANG, Y ;
WILSON, GS ;
THEVENOT, DR .
DIABETOLOGIA, 1992, 35 (03) :224-230