STATIC SECONDARY-ION MASS-SPECTROMETRY OF ADSORBED PROTEINS

被引:165
作者
MANTUS, DS
RATNER, BD
CARLSON, BA
MOULDER, JF
机构
[1] UNIV WASHINGTON,DEPT CHEM ENGN,BF-10,SEATTLE,WA 98195
[2] PERKIN ELMER PHYS ELECTR DIV,EDEN PRAIRIE,MN 55344
关键词
D O I
10.1021/ac00058a021
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Static secondary ion mass spectrometry (SIMS) was used to analyze proteins adsorbed to biomaterial surfaces. A spectral interpretation protocol was established by examining homopolymers of 16 amino acids. This protocol allows for the assignment of peaks unique to the various amino acids. Static SIMS was used to analyze plasma proteins adsorbed to titanium. The various factors that contributed to the relative intensities observed in the spectra were explored. The potential application of the technique for studying protein-fouled materials was investigated by analyzing a fouled sensor membrane.
引用
收藏
页码:1431 / 1438
页数:8
相关论文
共 54 条