IMPROVEMENTS IN THE REALIZATION OF THE QUANTIZED HALL RESISTANCE STANDARD AT OFMET

被引:19
作者
JECKELMANN, B [1 ]
FASEL, W [1 ]
JEANNERET, B [1 ]
机构
[1] SWISS FED INST TECHNOL,INST MICRO & OPTOELECTR,CH-1015 LAUSANNE,SWITZERLAND
关键词
D O I
10.1109/19.377827
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A measurement system based on a cryogenic current comparator has been developed at the Swiss Federal Office of Metrology (OFMET) to maintain the electrical unit of resistance. Standard resistors in the range of 1 Omega to 10 k Omega cain be measured against the quantized Hall resistance with an accuracy on the order of a few parts in 10(9). This recently completed system improves the measurement accuracy at OFMET in this range by 1 order of magnitude.
引用
收藏
页码:265 / 268
页数:4
相关论文
共 6 条
[1]   DC AND AC TECHNIQUES FOR RESISTANCE AND IMPEDANCE MEASUREMENTS [J].
DELAHAYE, F .
METROLOGIA, 1992, 29 (02) :81-93
[2]   QUANTIZED MAGNETORESISTANCE IN MULTIPLY CONNECTED PERIMETERS IN TWO-DIMENSIONAL SYSTEMS [J].
FANG, FF ;
STILES, PJ .
PHYSICAL REVIEW B, 1984, 29 (06) :3749-3751
[3]  
FELLER U, 1992 CONTR CCE M
[4]   THE CANADIAN REALIZATION OF A QUANTIZED HALL RESISTANCE STANDARD [J].
INGLIS, AD ;
WOOD, BM ;
YOUNG, B .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1993, 42 (02) :144-147
[5]   MATERIAL, DEVICE, AND STEP INDEPENDENCE OF THE QUANTIZED HALL RESISTANCE [J].
JECKELMANN, B ;
INGLIS, AD ;
JEANNERET, B .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1995, 44 (02) :269-272
[6]   COMPARISON OF THE QUANTIZED HALL RESISTANCE IN DIFFERENT GAAS/ALXGA1-XAS HETEROSTRUCTURES [J].
JECKELMANN, B ;
SCHWITZ, W ;
BUHLMANN, HJ ;
HOUDRE, R ;
ILEGEMS, M ;
JUCKNISCHKE, D ;
PY, MA .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1991, 40 (02) :231-233