LOCAL GEOMETRY VARIABLE CONDUCTANCE DIFFUSION FOR POSTRECONSTRUCTION FILTERING

被引:14
作者
LUO, DS
KING, MA
GLICK, S
机构
[1] Department of Nuclear Medicine, University of Massachusetts Medical Center, Worcester, MA
关键词
D O I
10.1109/23.340650
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Variable conductance diffusion (VCD) filtering can preserve edges while smoothing noise in an image. The threshold of the conductance function determines the degree to which a part of the image is smoothed. Traditionally, a constant threshold has been used. The use of a global threshold does not allow for adaptation to local variations within the image. The approach presented in this paper exploits the local geometry of the image and derives the threshold from the variations that are more likely caused by noise than by structural changes. We apply it to simulated noisy reconstructed single-photon emission computed tomographic (SPECT) image sets. For a particular voxel, if a consistent gradient direction is found within its neighborhood, then the variations on the plane perpendicular to the gradient direction are considered as noise and used to derive the threshold. Our results show that, for the same average noise level in the liver, the image contrast from both local geometry and constant threshold VCD filters are higher than those from Butterworth filtering. The local geometry VCD filtering provides images with smoother boundaries than the constant threshold method. Moreover, the contrast loss is less sensitive to the tumor size for the local geometry method.
引用
收藏
页码:2800 / 2806
页数:7
相关论文
共 11 条
[1]   IMAGE SELECTIVE SMOOTHING AND EDGE-DETECTION BY NONLINEAR DIFFUSION [J].
CATTE, F ;
LIONS, PL ;
MOREL, JM ;
COLL, T .
SIAM JOURNAL ON NUMERICAL ANALYSIS, 1992, 29 (01) :182-193
[2]   NONLINEAR ANISOTROPIC FILTERING OF MRI DATA [J].
GERIG, G ;
KUBLER, O ;
KIKINIS, R ;
JOLESZ, FA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1992, 11 (02) :221-232
[3]   NONITERATIVE COMPENSATION FOR THE DISTANCE-DEPENDENT DETECTOR RESPONSE AND PHOTON ATTENUATION IN SPECT IMAGING [J].
GLICK, SJ ;
PENNEY, BC ;
KING, MA ;
BYRNE, CL .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1994, 13 (02) :363-374
[4]  
LUO DS, 1992, 1992 IEEE NUCL SCI S, P1041
[5]   SCALE-SPACE AND EDGE-DETECTION USING ANISOTROPIC DIFFUSION [J].
PERONA, P ;
MALIK, J .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1990, 12 (07) :629-639
[6]  
RAHIMIAN J, 1984, MED PHYS, V11, P404
[7]  
SAUER K, 1991, IEEE T MED IMAGING, V10, P99
[8]  
WHITAKER RT, 1993, CVGIP-IMAG UNDERSTAN, V57, P99, DOI 10.1006/ciun.1993.1006
[9]  
WHITAKER RT, 1993, LECTURE NOTES COMPUT, V687, P149
[10]   NOISE PROPERTIES OF FILTERED-BACKPROJECTION AND ML-EM RECONSTRUCTED EMISSION TOMOGRAPHIC-IMAGES [J].
WILSON, DW ;
TSUI, BMW .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (04) :1198-1203