AN AUTOMATED ANALYTICAL METHOD FOR THE DETERMINATION OF FELBAMATE IN HUMAN PLASMA BY ROBOTIC SAMPLE PREPARATION AND REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY

被引:18
作者
HEMPENIUS, J [1 ]
HENDRIKS, G [1 ]
HINGSTMAN, J [1 ]
MENSINK, CK [1 ]
JONKMAN, JHG [1 ]
LIN, CC [1 ]
机构
[1] SCHERING PLOUGH RES INST,KENILWORTH,NJ 07033
关键词
FELBAMATE; BIOANALYSIS; ROBOTIC SAMPLE PREPARATION; HPLC;
D O I
10.1016/0731-7085(94)00087-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An automated analytical method for the determination of felbamate in human plasma is described. Sample cleanup and preparation was performed by means of a Zymate II laboratory robot and consisted of a liquid-liquid extraction of felbamate and the internal standard, primidone, from human plasma to dichloromethane. The dichloromethane was evaporated and reconstituted in a phosphate buffer. Separation was performed by reversed-phase high performance liquid chromatography using a 5 mu m Hypersil(R) ODS column (150 x 4.6 mm) and a mobile phase consisting of a mixture of phosphate buffer (pH = 6.5, 0.015 M) and acetonitrile (79:21, v/v). Quantitation was performed by measurement of the UV absorbance at a wavelength of 210 nm. The lower limit of quantitation was 0.100 mu g ml(-1) using 200 mu l of plasma. The mean absolute analytical recovery of felbamate was 75.2% (n = 28). The recovery of the internal standard, primidone was 74.7% (n = 10). The within-day precision was below 3.8% at all concentration levels, except at the lower limit of quantitation (18.3%). The within-day accuracy varied between -3.7 and +7.4%. The between-day precision was below 5.0% at all concentration levels. The between-day accuracy of the method varied between -5.7 and +1.6%. The selectivity of the method towards several other anti-epileptic drugs has been demonstrated.
引用
收藏
页码:1443 / 1451
页数:9
相关论文
共 6 条
[1]   DETERMINATION OF THE ANTICONVULSANT FELBAMATE IN BEAGLE DOG PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
CLARK, LA ;
WICHMANN, JK ;
KUCHARCZYK, N ;
SOFIA, RD .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1992, 573 (01) :113-119
[2]   EXTENSION OF SAMPLE SIZES AND PERCENTAGE POINTS FOR SIGNIFICANCE TESTS OF OUTLYING OBSERVATIONS [J].
GRUBBS, FE ;
BECK, G .
TECHNOMETRICS, 1972, 14 (04) :847-&
[3]   DEVELOPMENT OF A LABORATORY ROBOTIC SYSTEM FOR AUTOMATED BIOANALYTICAL METHODS .1. THE DETERMINATION OF THEOPHYLLINE IN HUMAN PLASMA - A COMPARISON BETWEEN THE ROBOTIZED AND MANUAL METHOD [J].
HEMPENIUS, J ;
WIELING, J ;
JONKMAN, JHG ;
DENOORD, OE ;
COENEGRACHT, PMJ ;
DOORNBOS, DA .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1990, 8 (04) :313-320
[4]   SIMULTANEOUS ASSAY OF FELBAMATE PLUS CARBAMAZEPINE, PHENYTOIN, AND THEIR METABOLITES BY LIQUID-CHROMATOGRAPHY WITH MOBILE PHASE OPTIMIZATION [J].
REMMEL, RP ;
MILLER, SA ;
GRAVES, NM .
THERAPEUTIC DRUG MONITORING, 1990, 12 (01) :90-96
[5]   ANALYTICAL METHODS VALIDATION - BIOAVAILABILITY, BIOEQUIVALENCE, AND PHARMACOKINETIC STUDIES [J].
SHAH, VP ;
MIDHA, KK ;
DIGHE, S ;
MCGILVERAY, IJ ;
SKELLY, JP ;
YACOBI, A ;
LAYLOFF, T ;
VISWANATHAN, CT ;
COOK, CE ;
MCDOWALL, RD ;
PITTMAN, KA ;
SPECTOR, S .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1992, 81 (03) :309-312
[6]   DEVELOPMENT OF A LABORATORY ROBOTIC SYSTEM FOR AUTOMATED BIOANALYTICAL METHODS .2. A ROBOT COMPUTER-PROGRAM FOR GUARDING TOTALLY AUTOMATED BIOANALYTICAL METHODS [J].
WIELING, J ;
HEMPENIUS, J ;
JEURING, HJ ;
JONKMAN, JHG ;
COENEGRACHT, PMJ ;
DOORNBOS, DA .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1990, 8 (07) :577-582