FIGURES OF MERIT FOR COMPARING RECONSTRUCTION ALGORITHMS WITH A VOLUME-IMAGING PET SCANNER

被引:53
作者
KINAHAN, PE
KARP, JS
机构
[1] Dept. of Radiol., Pennsylvania Univ., Philadelphia, PA
关键词
D O I
10.1088/0031-9155/39/3/024
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
For volume-imaging PET scanners, no septa are used to maximize the sensitivity by collecting events oblique to the scanner axis. We answer two questions: (i) how does the performance of an image reconstruction algorithm for a volume-imaging PET scanner depend on its general dimensions? and (ii) at what point is a three-dimensional (3D) reconstruction algorithm needed for a volume-imaging scanner, as the axial extent is increased? A 3D reconstruction algorithm will accurately incorporate the oblique events in a reconstruction of the original source distribution. From simulations of an existing volume PET scanner with a maximum axial acceptance angle (+/-alpha) of alpha = 9 degrees, however, we show that the single-slice rebinning algorithm is a good compromise between sensitivity, speed, and accuracy when compared to standard two-dimensional reconstruction (alpha = 1 degrees), and a 3D reconstruction with alpha = 9 degrees. We also show with simulations that a new scanner with alpha = 27 degrees requires 3D, reconstruction in order to achieve maximum sensitivity without unacceptable losses in accuracy. Measurements of scanner performance are based on a series of figures of merit that characterize image quality and quantitative accuracy measured from a set of simulated test phantoms.
引用
收藏
页码:631 / 642
页数:12
相关论文
共 14 条
[1]  
DAUBEWITHERSPOON ME, 1987, J NUCL MED, V28, P1717
[2]  
DEFRISE M, 1991, 1991 IEEE NUCL SCI S, V3, P1919
[3]   A METHODOLOGY FOR TESTING FOR STATISTICALLY SIGNIFICANT DIFFERENCES BETWEEN FULLY 3D PET RECONSTRUCTION ALGORITHMS [J].
FURUIE, SS ;
HERMAN, GT ;
NARAYAN, TK ;
KINAHAN, PE ;
KARP, JS ;
LEWITT, RM ;
MATEJ, S .
PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (03) :341-354
[4]  
KARP JS, 1990, J NUCL MED, V31, P617
[5]   POSITRON EMISSION TOMOGRAPHY WITH A LARGE AXIAL ACCEPTANCE ANGLE - SIGNAL-TO-NOISE CONSIDERATIONS [J].
KARP, JS ;
KINAHAN, PE ;
MANKOFF, DA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1991, 10 (03) :249-255
[6]   EFFECT OF INCREASED AXIAL-FIELD OF VIEW ON THE PERFORMANCE OF A VOLUME PET SCANNER [J].
KARP, JS ;
KINAHAN, PE ;
MUEHLLEHNER, G ;
COUNTRYMAN, P .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1993, 12 (02) :299-306
[7]   ANALYTIC 3D IMAGE-RECONSTRUCTION USING ALL DETECTED EVENTS [J].
KINAHAN, PE ;
ROGERS, JG .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1989, 36 (01) :964-968
[8]  
KINAHAN PE, 1992, 1992 P IEEE NUCL SCI, V2, P904
[9]  
LEWITT RM, 1991, 1991 IEEE NUCL SCI S, V3, P2054
[10]   A COMPARISON OF PHYSICAL IMAGE QUALITY INDEXES AND OBSERVER PERFORMANCE IN THE RADIOGRAPHIC DETECTION OF NYLON BEADS [J].
LOO, LND ;
DOI, K ;
METZ, CE .
PHYSICS IN MEDICINE AND BIOLOGY, 1984, 29 (07) :837-856