THE USE OF AN ELECTRONIC PORTAL IMAGING DEVICE FOR EXIT DOSIMETRY AND QUALITY-CONTROL MEASUREMENTS

被引:80
作者
KIRBY, MC
WILLIAMS, PC
机构
[1] North Western Medical Physics Department, Christie Hospital, Manchester
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1995年 / 31卷 / 03期
关键词
PORTAL IMAGING; EXIT DOSIMETRY; QUALITY CONTROL;
D O I
10.1016/0360-3016(94)00388-2
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To determine ways in which electronic portal imaging devices (EPIDs) could be used to (a) measure exit doses for external beam radiotherapy and (b) perform quality control checks on linear accelerators. Methods and Materials: When imaging, our fluoroscopic EPID adjusts the gain, offset, and frame acquisition time of the charge coupled device (CCD) camera automatically, to allow for the range of photon transmissions through the patient, and to optimize the signal-to-noise ratio, However, our EPID can be programmed to act as an integrating dosemeter, EPID dosemeter measurements were made for 20 MV photons, for different field sizes and thicknesses of unit density phantom material placed at varying exit surface to detector distances, These were compared with simultaneous Silicon diode exit dose measurements, Our exit dosimetry technique was verified using an anthropomorphic type phantom, and some initial measurements have been made for patients treated with irregularly shaped 20 MV x-ray fields, In this dosimetry mode, our EPID was also used to measure certain quality control parameters, x-ray field flatness, and the verification of segmented intensity modulated field prescriptions. Results: Configured for dosimetry, our EPID exhibited a highly linear response, capable of resolving individual monitor units, Exit doses could be measured to within about 3% of that measured using Silicon diodes, Field flatness was determined to within 1.5% of Farmer dosemeter measurements, Segmented intensity modulated fields can be easily verified. Conclusions: Our EPID has the versatility to assess a range of parameters pertinent to the delivery of high quality, high precision radiotherapy, When configured appropriately, it can measure exit doses in vivo, with reasonable accuracy, perform certain quick quality control checks, and analyze segmented intensity modulated treatment fields.
引用
收藏
页码:593 / 603
页数:11
相关论文
共 36 条
[1]  
AMOLS HI, 1987, MED PHYS, V14, P483
[2]   RADIATION-FIELD EDGE-DETECTION IN PORTAL IMAGES [J].
BIJHOLD, J ;
GILHUIJS, KGA ;
VANHERK, M ;
MEERTENS, H .
PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (12) :1705-1710
[3]   METHODS OF IMAGE-RECONSTRUCTION FROM PROJECTIONS APPLIED TO CONFORMATION RADIOTHERAPY [J].
BORTFELD, T ;
BURKELBACH, J ;
BOESECKE, R ;
SCHLEGEL, W .
PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (10) :1423-1434
[4]   A REVIEW OF ELECTRONIC PORTAL IMAGING DEVICES (EPIDS) [J].
BOYER, AL ;
ANTONUK, L ;
FENSTER, A ;
VANHERK, M ;
MEERTENS, H ;
MUNRO, P ;
REINSTEIN, LE ;
WONG, J .
MEDICAL PHYSICS, 1992, 19 (01) :1-16
[5]   THE GENERATION OF INTENSITY-MODULATED FIELDS FOR CONFORMAL RADIOTHERAPY BY DYNAMIC COLLIMATION [J].
CONVERY, DJ ;
ROSENBLOOM, ME .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (06) :1359-1374
[6]   CONTRAST ENHANCEMENT OF PORTAL IMAGES BY SELECTIVE HISTOGRAM EQUALIZATION [J].
CROOKS, I ;
FALLONE, BG .
MEDICAL PHYSICS, 1993, 20 (01) :199-204
[7]   ROUTINE CLINICAL ONLINE PORTAL IMAGING FOLLOWED BY IMMEDIATE FIELD ADJUSTMENT USING A TELE-CONTROLLED PATIENT COUCH [J].
DENEVE, W ;
VANDENHEUVEL, F ;
DEBEUKELEER, M ;
COGHE, M ;
THON, L ;
DEROOVER, P ;
VANLANCKER, M ;
STORME, G .
RADIOTHERAPY AND ONCOLOGY, 1992, 24 (01) :45-54
[8]   IMAGE COMPARISON TECHNIQUES FOR USE WITH MEGAVOLTAGE IMAGING-SYSTEMS [J].
EVANS, PM ;
GILDERSLEVE, JQ ;
MORTON, EJ ;
SWINDELL, W ;
COLES, R ;
FERRARO, M ;
RAWLINGS, C ;
XIAO, ZR ;
DYER, J .
BRITISH JOURNAL OF RADIOLOGY, 1992, 65 (776) :701-709
[9]   AUTOMATIC ONLINE INSPECTION OF PATIENT SETUP IN RADIATION-THERAPY USING DIGITAL PORTAL IMAGES [J].
GILHUIJS, KGA ;
VANHERK, M .
MEDICAL PHYSICS, 1993, 20 (03) :667-677
[10]   A METHOD TO ANALYZE 2-DIMENSIONAL DAILY RADIOTHERAPY PORTAL IMAGES FROM AN ONLINE FIBEROPTIC IMAGING-SYSTEM [J].
GRAHAM, ML ;
CHENG, AY ;
GEER, LY ;
BINNS, WR ;
VANNIER, MW ;
WONG, JW .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 20 (03) :613-619