A COMPARATIVE-STUDY OF METHODS FOR THE REGISTRATION OF PAIRS OF RADIATION-FIELDS

被引:4
作者
LESZCZYNSKI, K
LOOSE, S
DUNSCOMBE, P
机构
[1] Dept. of Med. Phys., Northwestern Ontario Regional Cancer Centre, Sudbury, Ont.
关键词
D O I
10.1088/0031-9155/38/10/010
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Accurate techniques for the registration of pairs of radiation fields, usually derived from simulator and portal films, are required if on-line portal imaging is to be used with maximum benefit to the patient. We report a quantitative comparison of the performance of three groups of registration techniques applied to field pairs derived from fifty simulator and 135 portal images acquired during the routine radiotherapy of seventeen patients. Using the parameters of coverage and overcoverage we conclude that a method based on the combination of geometric moments up to order six outperforms both central plus individual Zernike moments up to order four and a generalized field-match-point method.
引用
收藏
页码:1493 / 1502
页数:10
相关论文
共 16 条
[1]   CORRELATION OF PROJECTION RADIOGRAPHS IN RADIATION-THERAPY USING OPEN CURVE SEGMENTS AND POINTS [J].
BALTER, JM ;
PELIZZARI, CA ;
CHEN, GTY .
MEDICAL PHYSICS, 1992, 19 (02) :329-334
[2]   AUTOMATIC VERIFICATION OF RADIATION-FIELD SHAPE USING DIGITAL PORTAL IMAGES [J].
BIJHOLD, J ;
GILHUIJS, KGA ;
VANHERK, M .
MEDICAL PHYSICS, 1992, 19 (04) :1007-1014
[3]   RADIATION-FIELD EDGE-DETECTION IN PORTAL IMAGES [J].
BIJHOLD, J ;
GILHUIJS, KGA ;
VANHERK, M ;
MEERTENS, H .
PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (12) :1705-1710
[4]   FAST EVALUATION OF PATIENT SET-UP DURING RADIOTHERAPY BY ALIGNING FEATURES IN PORTAL AND SIMULATOR IMAGES [J].
BIJHOLD, J ;
VANHERK, M ;
VIJLBRIEF, R ;
LEBESQUE, JV .
PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (12) :1665-1679
[5]  
Bissett R., 1992, International Journal of Radiation Oncology Biology Physics, V24, P216
[6]   ROUTINE CLINICAL ONLINE PORTAL IMAGING FOLLOWED BY IMMEDIATE FIELD ADJUSTMENT USING A TELE-CONTROLLED PATIENT COUCH [J].
DENEVE, W ;
VANDENHEUVEL, F ;
DEBEUKELEER, M ;
COGHE, M ;
THON, L ;
DEROOVER, P ;
VANLANCKER, M ;
STORME, G .
RADIOTHERAPY AND ONCOLOGY, 1992, 24 (01) :45-54
[7]   THE INVESTIGATION AND RECTIFICATION OF FIELD PLACEMENT ERRORS IN THE DELIVERY OF COMPLEX HEAD AND NECK FIELDS [J].
DUNSCOMBE, PB ;
FOX, K ;
LOOSE, S ;
LESZCZYNSKI, K .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 26 (01) :155-161
[8]   TEMPLATE MATCHING IN ROTATED IMAGES [J].
GOSHTASBY, A .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1985, 7 (03) :338-344
[9]   VISUAL-PATTERN RECOGNITION BY MOMENT INVARIANTS [J].
HU, M .
IRE TRANSACTIONS ON INFORMATION THEORY, 1962, 8 (02) :179-&
[10]  
LESZCZYNSKI K W, 1991, Medical Physics (Woodbury), V18, P616