FORMATION OF MULTIPLY-CHARGED IONS FROM LARGE MOLECULES USING MASSIVE-CLUSTER IMPACT

被引:40
作者
MAHONEY, JF [1 ]
CORNETT, DS [1 ]
LEE, TD [1 ]
机构
[1] CITY HOPE NATL MED CTR,BECKMAN RES INT,DEPT IMMUNOL,DUARTE,CA 91010
关键词
D O I
10.1002/rcm.1290080513
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Massive-cluster impact is demonstrated to be an effective ionization technique for the mass analysis of proteins as large as 17 kDa. The design of the cluster source permits coupling to both magnetic-sector and quadrupole mass spectrometers. Mass spectra are characterized by the almost total absence of chemical background and a predominance of multiply charged ions formed from 100% glycerol matrix. The number of charge states produced by the technique is observed to range from +3 to +9 for chicken egg lysozyme (14 310 Da). The lower m/z values provided by higher charge states increase the effective mass range of analyses performed with conventional ionization by fast-atom bombardment or liquid secondary ion mass spectrometry.
引用
收藏
页码:403 / 406
页数:4
相关论文
共 11 条
[1]   SECONDARY ION MASS-SPECTROMETRY WITH CESIUM ION PRIMARY BEAM AND LIQUID TARGET MATRIX FOR ANALYSIS OF BIOORGANIC COMPOUNDS [J].
ABERTH, W ;
STRAUB, KM ;
BURLINGAME, AL .
ANALYTICAL CHEMISTRY, 1982, 54 (12) :2029-2034
[2]   EFFECT OF PRIMARY BEAM ENERGY ON THE SECONDARY ION SPUTTERING EFFICIENCY OF LIQUID SECONDARY IONIZATION MASS-SPECTROMETRY IN THE 5-30-KEV RANGE [J].
ABERTH, WH ;
BURLINGAME, AL .
ANALYTICAL CHEMISTRY, 1988, 60 (14) :1426-1428
[3]   COMPARISON OF POLYATOMIC AND ATOMIC PRIMARY BEAMS FOR SECONDARY ION MASS-SPECTROMETRY OF ORGANICS [J].
APPELHANS, AD ;
DELMORE, JE .
ANALYTICAL CHEMISTRY, 1989, 61 (10) :1087-1093
[4]   FAST ATOM BOMBARDMENT OF SOLIDS (FAB) - A NEW ION-SOURCE FOR MASS-SPECTROMETRY [J].
BARBER, M ;
BORDOLI, RS ;
SEDGWICK, RD ;
TYLER, AN .
JOURNAL OF THE CHEMICAL SOCIETY-CHEMICAL COMMUNICATIONS, 1981, (07) :325-327
[5]   MASS DISTRIBUTIONS OF IONS SPUTTERED BY CLUSTER IMPACTS ON CARBON, COPPER AND GOLD TARGETS [J].
BEUHLER, RJ ;
FRIEDMAN, L .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1989, 94 (1-2) :25-39
[6]   EFFECTS OF PRIMARY ION POLYATOMICITY AND KINETIC-ENERGY ON SECONDARY ION YIELD AND INTERNAL ENERGY IN SIMS [J].
HAND, OW ;
MAJUMDAR, TK ;
COOKS, RG .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1990, 97 (01) :35-45
[7]   MASSIVE CLUSTER IMPACT MASS-SPECTROMETRY - A NEW DESORPTION METHOD FOR THE ANALYSIS OF LARGE BIOMOLECULES [J].
MAHONEY, JF ;
PEREL, J ;
RUATTA, SA ;
MARTINO, PA ;
HUSAIN, S ;
LEE, TD .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1991, 5 (10) :441-445
[8]   SHOCK-WAVE MODEL FOR SPUTTERING BIOMOLECULES USING MASSIVE CLUSTER IMPACTS [J].
MAHONEY, JF ;
PEREL, J ;
LEE, TD ;
MARTINO, PA ;
WILLIAMS, P .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1992, 3 (04) :311-317
[9]   LIQUID SECONDARY ION MASS-SPECTROMETRIC ANALYSIS OF NATURAL AND RECOMBINANT PROTEINS AND MONOCLONAL-ANTIBODY LIGHT-CHAINS WITH MOLECULAR-WEIGHTS BETWEEN 16000 AND 25000 [J].
SIEGEL, MM ;
TSAO, RS ;
DOELLING, VW ;
HOLLANDER, IJ .
ANALYTICAL CHEMISTRY, 1990, 62 (14) :1536-1542
[10]   CF-252 PLASMA DESORPTION MASS-SPECTROMETRY [J].
SUNDQVIST, B ;
MACFARLANE, RD .
MASS SPECTROMETRY REVIEWS, 1985, 4 (04) :421-460