RETENTION BEHAVIOR OF TRIBUTYLPHENOL ETHYLENE-OXIDE OLIGOMERS ON AN ALUMINA HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC COLUMN

被引:14
作者
FORGACS, E [1 ]
CSERHATI, T [1 ]
机构
[1] HUNGARIAN ACAD SCI,CENT RES INST CHEM,H-1025 BUDAPEST,HUNGARY
关键词
D O I
10.1016/0021-9673(93)E0829-J
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The retention behaviour of tributylphenol ethylene oxide oligomer surfactants was studied on an alumina HPLC column using ethyl acetate-n-hexane mixtures as eluents. The surfactants contained various numbers of ethylene oxide groups per molecule and tributylphenol isomers as hydrophobic moieties. The column separated the surfactants according to the length of the ethylene oxide chain and the position of butyl substituents in one run, demonstrating the good separation power of alumina. A significant linear correlation was found between the logarithm of the capacity factor of each surfactant and the concentration of ethyl acetate in the eluent, but the dependence of the retention on the ethyl acetate concentration was low. Stepwise regression analysis indicated that the number of ethylene oxide groups per molecule has a greater effect than the position of the butyl substituents in the tributylphenol moiety on the retention.
引用
收藏
页码:239 / 243
页数:5
相关论文
共 25 条
[1]   REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF ANIONIC AND ETHOXYLATED NONIONIC SURFACTANTS AND PESTICIDES IN LIQUID PESTICIDE FORMULATIONS [J].
BAN, T ;
PAPP, E ;
INCZEDY, J .
JOURNAL OF CHROMATOGRAPHY, 1992, 593 (1-2) :227-231
[2]   SURFACE SILANOLS IN SILICA-BONDED HYDROCARBONACEOUS STATIONARY PHASES .2. IRREGULAR RETENTION BEHAVIOR AND EFFECT OF SILANOL MASKING [J].
BIJ, KE ;
HORVATH, C ;
MELANDER, WR ;
NAHUM, A .
JOURNAL OF CHROMATOGRAPHY, 1981, 203 (JAN) :65-84
[3]   STUDY OF THE FLUORIDE ADSORPTION CHARACTERISTICS OF POROUS MICROPARTICULATE ZIRCONIUM-OXIDE [J].
BLACKWELL, JA ;
CARR, PW .
JOURNAL OF CHROMATOGRAPHY, 1991, 549 (1-2) :43-57
[4]   PREPARATION OF CATALYSTS BY METALLIC COMPLEX ADSORPTION ON MINERAL OXIDES [J].
BRUNELLE, JP .
PURE AND APPLIED CHEMISTRY, 1978, 50 (9-10) :1211-1229
[5]   RETENTION CHARACTERISTICS OF AN ALUMINUM-OXIDE HPLC COLUMN [J].
CSERHATI, T .
CHROMATOGRAPHIA, 1990, 29 (11-12) :593-596
[6]   POROUS GRAPHITIZED CARBON AND OCTADECYLSILICA COLUMNS IN THE SEPARATION OF SOME MONOAMINE-OXIDASE INHIBITORY DRUGS [J].
FORGACS, E ;
VALKO, K ;
CSERHATI, T ;
MAGYAR, K .
JOURNAL OF CHROMATOGRAPHY, 1993, 631 (1-2) :207-213
[7]  
HAGER H, 1982, MODERNE REGRESSIONAN, P135
[8]  
Hansch C, 1979, SUBSTITUENT CONSTANT, P1
[9]   DETERMINATION OF HYDROPHOBICITY PARAMETERS ON POLYBUTADIENE-COATED ALUMINA AND THEIR APPLICATION IN QUANTITATIVE STRUCTURE-ACTIVITY-RELATIONSHIPS ANALYSIS [J].
KALISZAN, R ;
PETRUSEWICZ, J ;
BLAIN, RW ;
HARTWICK, RA .
JOURNAL OF CHROMATOGRAPHY, 1988, 458 :395-404
[10]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF HEROIN SAMPLES ON ALUMINA BY ION-EXCHANGE IN MIXED AQUEOUS-ORGANIC MOBILE PHASES [J].
LAURENT, CJCM ;
BILLIET, HAH ;
DEGALAN, L .
JOURNAL OF CHROMATOGRAPHY, 1984, 285 (01) :161-170