GLUTAMATE OXIDASE ENZYME ELECTRODES - MICROSENSORS FOR NEUROTRANSMITTER DETERMINATION USING ELECTROCHEMICALLY POLYMERIZED PERMSELECTIVE FILMS

被引:71
作者
COOPER, JM
FOREMAN, PL
GLIDLE, A
LING, TW
PRITCHARD, DJ
机构
[1] Department of Electronics and Electrical Engineering, University of Glasgow, Glasgow
来源
JOURNAL OF ELECTROANALYTICAL CHEMISTRY | 1995年 / 388卷 / 1-2期
关键词
ENZYME MICROSENSORS; ELECTROPOLYMERIZATION; NEUROTRANSMITTERS; GLUTAMATE OXIDASE; PERMSELECTIVE FILMS;
D O I
10.1016/0022-0728(95)03846-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Enzyme entrapment in electrochemically polymerized membranes is an attractive method for the development of stable reproducible enzyme microsensors with fast response times. In this paper the development of a biosensor for the determination of glutamate, involving the entrapment of the enzyme glutamate oxidase in two different electropolymerization matrices, is described. Subsequently, the kinetics of the immobilized enzyme in the different matrices are compared, and the role of the polymers in providing a permselective barrier for the exclusion of potential electroactive interferents are characterized.
引用
收藏
页码:143 / 149
页数:7
相关论文
共 20 条
[1]   ELECTROCHEMICAL IMMOBILIZATION OF ENZYMES .1. THEORY [J].
BARTLETT, PN ;
WHITAKER, RG .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1987, 224 (1-2) :27-35
[2]   ELECTROCHEMICAL IMMOBILIZATION OF ENZYMES .3. IMMOBILIZATION OF GLUCOSE-OXIDASE IN THIN-FILMS OF ELECTROCHEMICALLY POLYMERIZED PHENOLS [J].
BARTLETT, PN ;
TEBBUTT, P ;
TYRRELL, CH .
ANALYTICAL CHEMISTRY, 1992, 64 (02) :138-142
[3]   ELECTROCHEMICAL IMMOBILIZATION OF ENZYMES .2. GLUCOSE-OXIDASE IMMOBILIZED IN POLY-N-METHYLPYRROLE [J].
BARTLETT, PN ;
WHITAKER, RG .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1987, 224 (1-2) :37-48
[4]   ELECTROCHEMICAL IMMOBILIZATION OF ENZYMES .6. MICROELECTRODES FOR THE DETECTION OF L-LACTATE BASED ON FLAVOCYTOCHROME B(2) IMMOBILIZED IN A POLY(PHENOL) FILM [J].
BARTLETT, PN ;
CARUANA, DJ .
ANALYST, 1994, 119 (02) :175-180
[5]  
BARTLETT PN, 1993, J ELECTROANAL CHEM, V362, P1
[6]  
BARTLETT PN, 1993, ANALYST, V117, P1287
[7]   CORRELATION OF THE EXTRACELLULAR GLUTAMATE CONCENTRATION WITH EXTENT OF BLOOD-FLOW REDUCTION AFTER SUBDURAL-HEMATOMA IN THE RAT [J].
BULLOCK, R ;
BUTCHER, SP ;
CHEN, MH ;
KENDALL, L ;
MCCULLOCH, J .
JOURNAL OF NEUROSURGERY, 1991, 74 (05) :794-802
[8]   AMPEROMETRIC ENZYME ELECTRODE FOR THE DETERMINATION OF ASPARTATE-AMINOTRANSFERASE AND ALANINE AMINOTRANSFERASE IN SERUM [J].
COOPER, JM ;
MCNEIL, CJ ;
SPOORS, JA .
ANALYTICA CHIMICA ACTA, 1991, 245 (01) :57-62
[9]  
COOPER JM, 1994, J MATER SCI-MATER EL, V5, P111
[10]   EVIDENCE FOR THE FUNCTIONAL MECHANISM OF A POLYPYRROLE GLUCOSE-OXIDASE ELECTRODE [J].
COOPER, JM ;
BLOOR, D .
ELECTROANALYSIS, 1993, 5 (9-10) :883-886