VARIABLE COMPENSATION CHEST RADIOGRAPHY PERFORMED WITH A COMPUTED RADIOGRAPHY SYSTEM - DESIGN CONSIDERATIONS AND INITIAL CLINICAL-EXPERIENCE

被引:6
作者
DOBBINS, JT
RICE, JJ
GOODMAN, PC
PATZ, EF
RAVIN, CE
机构
[1] Thoracis Research Division, Department of Radiology, Duke University Medical Center, Durham
关键词
IMAGES; PROCESSING; LUNG; RADIOGRAPHY; MEDIASTINUM; DIGITAL; STORAGE PHOSPHOR; TECHNOLOGY;
D O I
10.1148/radiology.187.1.8451437
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The authors describe a variable compensation (VC) technique in which an x-ray equalizer and a computed radiography system are used. The VC technique allows retrospective alteration of equalized chest appearance with maintenance of improved signal-to-noise ratio in dense regions. Two imaging plates are used: one upstream of the patient to record the incident beam profile and one downstream to record the equalized image. Subtraction of a weighted version of the upstream image from the downstream image permits alteration of the appearance of the VC image, from the extremes of simulated-unequalized to highly equalized. VC image appearance was optimized with a real-time workstation. The quality of VC images obtained in 33 patients was evaluated by three chest radiologists. Mediastinal appearance was better on VC equalized images than on conventional screen-film images. The simulation of the appearance of a conventional radiograph with VC proved useful in interpretation of lung appearances on equalized radiographs.
引用
收藏
页码:55 / 63
页数:9
相关论文
共 21 条
[1]   THE INFLUENCE OF AMBIENT AND VIEWBOX LIGHT UPON VISUAL DETECTION OF LOW-CONTRAST TARGETS IN A RADIOGRAPH [J].
ALTER, AJ ;
KARGAS, GA ;
KARGAS, SA ;
CAMERON, JR ;
MCDERMOTT, JC .
INVESTIGATIVE RADIOLOGY, 1982, 17 (04) :402-406
[2]   CHANGES IN LESION DETECTABILITY CAUSED BY LIGHT ADAPTATION IN RETINAL PHOTORECEPTORS [J].
BAXTER, B ;
RAVINDRA, H ;
NORMANN, RA .
INVESTIGATIVE RADIOLOGY, 1982, 17 (04) :394-401
[3]   SCATTER FRACTIONS IN AMBER IMAGING [J].
CHOTAS, HG ;
FLOYD, CE ;
DOBBINS, JT ;
LO, JY ;
RAVIN, CE .
RADIOLOGY, 1990, 177 (03) :879-880
[4]   THRESHOLD PERCEPTION PERFORMANCE WITH COMPUTED AND SCREEN-FILM RADIOGRAPHY - IMPLICATIONS FOR CHEST RADIOGRAPHY [J].
DOBBINS, JT ;
RICE, JJ ;
BEAM, CA ;
RAVIN, CE .
RADIOLOGY, 1992, 183 (01) :179-187
[5]   VARIABLE COMPENSATION TECHNIQUE FOR DIGITAL RADIOGRAPHY OF THE CHEST [J].
DOBBINS, JT ;
POWELL, AO .
RADIOLOGY, 1989, 173 (02) :451-458
[6]  
DOBBINS JT, 1989, Patent No. 4868857
[7]  
DOBBINS JT, Patent No. 5081659
[8]  
DOBBINS JT, 1987, 1987 P CHEST IM C MA, P144
[9]   STORAGE PHOSPHOR RADIOGRAPHS VS CONVENTIONAL FILMS - INTERPRETERS PERCEPTIONS OF DIAGNOSTIC QUALITY [J].
FUHRMAN, CR ;
GUR, D ;
GOOD, B ;
ROCKETTE, H ;
COOPERSTEIN, LA ;
FEIST, JH .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 150 (05) :1011-1014
[10]   DIGITAL BEAM ATTENUATOR TECHNIQUE FOR COMPENSATED CHEST RADIOGRAPHY [J].
HASEGAWA, BH ;
NAIMUDDIN, S ;
DOBBINS, JT ;
MISTRETTA, CA ;
PEPPLER, WW ;
HANGIANDREOU, NJ ;
CUSMA, JT ;
MCDERMOTT, JC ;
KUDVA, BV ;
MELBYE, KM .
RADIOLOGY, 1986, 159 (02) :537-543