SEPARATION OF POLYCYCLIC AROMATIC-HYDROCARBONS BY MICELLAR ELECTROKINETIC CHROMATOGRAPHY WITH LASER FLUORESCENCE DETECTION

被引:29
作者
KANETA, T [1 ]
YAMASHITA, T [1 ]
IMASAKA, T [1 ]
机构
[1] KYUSHU UNIV,FAC ENGN,DEPT CHEM SCI & TECHNOL,FUKUOKA 812,JAPAN
关键词
CHROMATOGRAPHY; FLUOROMETRY; LASER SPECTROSCOPY; PAHS; MICELLAR ELECTROKINETIC CHROMATOGRAPHY;
D O I
10.1016/0003-2670(94)00317-F
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Polycyclic aromatic hydrocarbons (PAHs) were separated by micellar electrokinetic chromatography and were detected by laser fluorometry. The PAHs with large molecular weights were separated by using dimethylformamide as an organic modifier. A He-Cd laser (325 nm, 5 mW) or a blue semiconductor laser (415 nm, 50 mu W) was used as an exciting light source. The detection limit (S/N = 3) for perylene was 1.4 X 10(-7) M under He-Cd laser excitation or 3.4 x 10(-7) M under semiconductor laser excitation.
引用
收藏
页码:371 / 375
页数:5
相关论文
共 20 条
[1]  
BALACHUNAS AT, 1988, ANAL CHEM, V60, P617
[2]   EXTENSION OF ELUTION RANGE IN MICELLAR ELECTROKINETIC CAPILLARY CHROMATOGRAPHY [J].
BALCHUNAS, AT ;
SEPANIAK, MJ .
ANALYTICAL CHEMISTRY, 1987, 59 (10) :1466-1470
[3]  
BUSHEY MM, 1989, J MICROCOLUMN SEP, V1, P125
[4]   BILE-SALT SURFACTANTS IN MICELLAR ELECTROKINETIC CAPILLARY CHROMATOGRAPHY - APPLICATION TO HYDROPHOBIC MOLECULE SEPARATIONS [J].
COLE, RO ;
SEPANIAK, MJ ;
HINZE, WL ;
GORSE, J ;
OLDIGES, K .
JOURNAL OF CHROMATOGRAPHY, 1991, 557 (1-2) :113-123
[5]   ON-COLUMN FLUORESCENCE DETECTOR FOR OPEN-TUBULAR CAPILLARY LIQUID-CHROMATOGRAPHY [J].
GUTHRIE, EJ ;
JORGENSON, JW .
ANALYTICAL CHEMISTRY, 1984, 56 (03) :483-486
[6]   QUALITATIVE-ANALYSIS OF MYCOTOXINS USING MICELLAR ELECTROKINETIC CAPILLARY CHROMATOGRAPHY [J].
HOLLAND, RD ;
SEPANIAK, MJ .
ANALYTICAL CHEMISTRY, 1993, 65 (09) :1140-1146
[7]   DETERMINATION OF ANTHRACENE-DERIVATIVES BY CYCLODEXTRIN-MODIFIED MICELLAR ELECTROKINETIC CHROMATOGRAPHY COMBINED WITH HELIUM CADMIUM LASER FLUOROMETRY [J].
IMASAKA, T ;
NISHITANI, K ;
ISHIBASHI, N .
ANALYTICA CHIMICA ACTA, 1992, 256 (01) :3-7
[8]   CYCLODEXTRIN-MODIFIED MICELLAR ELECTROKINETIC CHROMATOGRAPHY COMBINED WITH SEMICONDUCTOR-LASER FLUOROMETRY [J].
IMASAKA, T ;
NISHITANI, K ;
ISHIBASHI, N .
ANALYST, 1991, 116 (12) :1407-1409
[9]  
KANETA T, IN PRESS ELECTROPHOR
[10]   GENERATION OF 41 MW OF BLUE RADIATION BY FREQUENCY DOUBLING OF A GAALAS DIODE-LASER [J].
KOZLOVSKY, WJ ;
LENTH, W ;
LATTA, EE ;
MOSER, A ;
BONA, GL .
APPLIED PHYSICS LETTERS, 1990, 56 (23) :2291-2292