SINGLES TRANSMISSION IN VOLUME-IMAGING PET WITH A CS-137 SOURCE

被引:110
作者
KARP, JS
MUEHLLEHNER, G
QU, H
YAN, XH
机构
[1] UGM MED SYST,PHILADELPHIA,PA 19104
[2] UNIV PENN,DEPT PSYCHIAT,PHILADELPHIA,PA 19104
关键词
D O I
10.1088/0031-9155/40/5/014
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The feasibility of a new method of attenuation correction in PET has been investigated, using a single-photon emitter for the transmission scan. The transmission scan is predicted to be more than a factor of ten faster with the singles method than the standard coincidence method, for comparable statistics. Thus, a transmission scan can be completed in 1-2 min, rather than 10-20 min, as is common practice with the coincidence method. In addition, a potential advantage of using the single-photon source Cs-137, which has an energy of 662 keV, is that postinjection transmission studies can be performed using energy discrimination to separate the transmission from the emission data at 511 keV. In order to compensate for the energy difference of the attenuation coefficients at 662 keV compared to 511 keV, the transmission images are segmented into two compartments, tissue and lung, and known values (for 511 keV) of attenuation are inserted into these compartments. This technique also compensates for the higher amount of scatter present with the singles method, since it is not possible to use a position gate (based on collinearity of the source and two detector positions) as is commonly done with a positron-emitting source. We have demonstrated, with experimental phantom studies, that the singles transmission method combined with segmentation gives results equivalent both qualitatively and quantitatively to the coincidence method, but requires significantly less time.
引用
收藏
页码:929 / 944
页数:16
相关论文
共 24 条
  • [1] BAILEY DL, 1987, J NUCL MED, V28, P844
  • [2] DETERMINATION OF OBJECT CONTOUR FROM PROJECTIONS FOR ATTENUATION CORRECTION IN CRANIAL POSITRON EMISSION TOMOGRAPHY
    BERGSTROM, M
    LITTON, J
    ERIKSSON, L
    BOHM, C
    BLOMQVIST, G
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1982, 6 (02) : 365 - 372
  • [3] Carroll LR, 1983, EMISSION COMPUTED TO, P235
  • [4] DAUBEWITHERSPOO.ME, 1988, IEEE T NUCL SCI, V35, P757
  • [5] ATTENUATION CORRECTION IN PET USING SINGLE-PHOTON TRANSMISSION MEASUREMENT
    DEKEMP, RA
    NAHMIAS, C
    [J]. MEDICAL PHYSICS, 1994, 21 (06) : 771 - 778
  • [6] AN INVESTIGATION OF SCATTER IN ATTENUATION CORRECTION FOR PET
    DIGBY, WM
    HOFFMAN, EJ
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1989, 36 (01) : 1038 - 1042
  • [7] PRACTICAL CONE-BEAM ALGORITHM
    FELDKAMP, LA
    DAVIS, LC
    KRESS, JW
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06): : 612 - 619
  • [8] DESIGN AND PERFORMANCE OF THE HEAD PENN-PET SCANNER
    FREIFELDER, R
    KARP, JS
    GEAGAN, M
    MUEHLLEHNER, G
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1994, 41 (04) : 1436 - 1440
  • [9] FREY EC, 1992, J NUCL MED, V33, P2238
  • [10] HUANG SC, 1981, J NUCL MED, V22, P627