STANFORD 3D HYPERTHERMIA TREATMENT PLANNING SYSTEM - TECHNICAL REVIEW AND CLINICAL SUMMARY

被引:46
作者
SULLIVAN, DM
BENYOSEF, R
KAPP, DS
机构
[1] Department of Radiation Oncology, Stanford University School of Medicine, Stanford
关键词
DEEP HYPERTHERMIA; 3D SAR MODELING; TREATMENT PLANNING; OPTIMIZATION;
D O I
10.3109/02656739309032052
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
In the field of deep regional hyperthermia cancer therapy the Sigma 60 applicator of the BSD-2000 Hyperthermia System is one of the most widely used devices. This device employs four independent sources of radiofrequency electromagnetic energy to heat tumour sites deep within the body. The difficulty in determining the input parameters for the four sources has motivated the development of a computer-based three-dimensional (3D) treatment planning system. The Stanford 3D Hyperthermia Treatment Planning System has been in clinical use at Stanford Medical Center for the past 2 years. It utilizes a patient-specific, three-dimensional computer simulation to determine safe and effective power deposition plans. An optimization programme for the selection of the amplitudes, phases and frequency for the sources has been developed and used in the clinic. Examples of the application of the treatment planning for hyperthermia treatment of pulmonary, pelvic, and mediastinal tumours are presented. Methods for quantifying the relative effectiveness of various treatment plans are reviewed.
引用
收藏
页码:627 / 643
页数:17
相关论文
共 26 条
[1]   DOSE VOLUME HISTOGRAM ANALYSIS OF LIVER RADIATION TOLERANCE [J].
AUSTINSEYMOUR, MM ;
CHEN, GTY ;
CASTRO, JR ;
SAUNDERS, WM ;
PITLUCK, S ;
WOODRUFF, KH ;
KESSLER, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1986, 12 (01) :31-35
[2]   PERIPHERAL NEUROPATHY AND MYONECROSIS FOLLOWING HYPERTHERMIA AND RADIATION-THERAPY FOR RECURRENT PROSTATIC-CANCER - CORRELATION OF DAMAGE WITH PREDICTED SAR PATTERN [J].
BENYOSEF, R ;
SULLIVAN, DM ;
KAPP, DS .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 1992, 8 (02) :173-185
[3]   DIRECT USE OF CT SCANS FOR HYPERTHERMIA TREATMENT PLANNING [J].
JAMES, BJ ;
SULLIVAN, DM .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1992, 39 (08) :845-851
[4]   CREATION OF 3-DIMENSIONAL PATIENT MODELS FOR HYPERTHERMIA TREATMENT PLANNING [J].
JAMES, BJ ;
SULLIVAN, DM .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1992, 39 (03) :238-242
[5]   NONIONIZING ELECTROMAGNETIC WAVE EFFECTS IN BIOLOGICAL-MATERIALS AND SYSTEMS [J].
JOHNSON, CC ;
GUY, AW .
PROCEEDINGS OF THE INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS, 1972, 60 (06) :692-&
[6]   BLADDER COOLING IN PATIENTS TREATED WITH REGIONAL HYPERTHERMIA OF THE PELVIS USING AN ANNULAR PHASED-ARRAY [J].
KAPP, DS ;
PRIONAS, SD ;
FESSENDEN, P ;
LIU, FF ;
LEE, ER ;
LOHRBACH, AW .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1988, 14 (06) :1307-1310
[7]  
KNOX SJ, 1988, CANCER, V62, P1479, DOI 10.1002/1097-0142(19881015)62:8<1479::AID-CNCR2820620806>3.0.CO
[8]  
2-H
[9]   POTENTIAL HAZARDS OF RADIATIVE ELECTROMAGNETIC HYPERTHERMIA IN THE PRESENCE OF MULTIPLE METALLIC SURGICAL CLIPS [J].
LEE, ER ;
SULLIVAN, DM ;
KAPP, DS .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 1992, 8 (06) :809-817
[10]   A FREQUENCY-DEPENDENT FINITE-DIFFERENCE TIME-DOMAIN FORMULATION FOR DISPERSIVE MATERIALS [J].
LUEBBERS, R ;
HUNSBERGER, FP ;
KUNZ, KS ;
STANDLER, RB ;
SCHNEIDER, M .
IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 1990, 32 (03) :222-227