REDUCED PHASE-ENCODING IN SPECTROSCOPIC IMAGING

被引:109
作者
MAUDSLEY, AA
MATSON, GB
HUGG, JW
WEINER, MW
机构
[1] UNIV CALIF SAN FRANCISCO, DEPT RADIOL, SAN FRANCISCO, CA 94143 USA
[2] UNIV CALIF SAN FRANCISCO, DEPT PHARMACEUT CHEM, SAN FRANCISCO, CA 94143 USA
[3] UNIV CALIF SAN FRANCISCO, DEPT MED, SAN FRANCISCO, CA USA
关键词
MR; SPECTROSCOPIC IMAGING; K-SPACE;
D O I
10.1002/mrm.1910310610
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The effect of different spatial-encoding (k-space) sampling distributions are evaluated for magnetic resonance spectroscopic imaging (MRSI) using Fourier reconstruction. Previously, most MRSI studies have used square or cubic k-space functions, symmetrically distributed. These studies examine the conventional k-space distribution with spherical distribution, and 1/2 k-space acquisition, using computer simulation studies of the MRSI acquisition for three spatial dimensions and experimental results. Results compare the spatial response function, Gibbs ringing effects, and signal contamination for different spatial-encoding distribution functions. Results indicate that spherical encoding, in comparison with cubic encoding, results in a modest improvement of the response function with approximately equivalent spatial resolution for the same acquisition time. For spin-echo acquired data, reduced acquisition times can readily be obtained using 1/2 k-space methods, with a concomitant reduction in signal to noise ratio.
引用
收藏
页码:645 / 651
页数:7
相关论文
共 20 条
[11]   CORRECTION OF SPATIALLY DEPENDENT PHASE-SHIFTS FOR PARTIAL FOURIER-IMAGING [J].
MACFALL, JR ;
PELC, NJ ;
VAVREK, RM .
MAGNETIC RESONANCE IMAGING, 1988, 6 (02) :143-155
[12]   ESSENTIAL CONSIDERATIONS FOR SPECTRAL LOCALIZATION USING INDIRECT GRADIENT ENCODING OF SPATIAL INFORMATION [J].
MARECI, TH ;
BROOKER, HR .
JOURNAL OF MAGNETIC RESONANCE, 1991, 92 (02) :229-246
[13]  
MARGOSIAN P, 1986, Health Care Instrumentation, V1, P195
[14]   SENSITIVITY IN FOURIER-IMAGING [J].
MAUDSLEY, AA .
JOURNAL OF MAGNETIC RESONANCE, 1986, 68 (02) :363-366
[15]   SPECTROSCOPIC IMAGING DISPLAY AND ANALYSIS [J].
MAUDSLEY, AA ;
LIN, E ;
WEINER, MW .
MAGNETIC RESONANCE IMAGING, 1992, 10 (03) :471-485
[16]   SPATIALLY RESOLVED HIGH-RESOLUTION SPECTROSCOPY BY 4-DIMENSIONAL NMR [J].
MAUDSLEY, AA ;
HILAL, SK ;
PERMAN, WH ;
SIMON, HE .
JOURNAL OF MAGNETIC RESONANCE, 1983, 51 (01) :147-152
[17]   SPIN-ECHO P-31 SPECTROSCOPIC IMAGING IN THE HUMAN BRAIN [J].
MAUDSLEY, AA ;
TWIEG, DB ;
SAPPEYMARINIER, D ;
HUBESCH, B ;
HUGG, JW ;
MATSON, GB ;
WEINER, MW .
MAGNETIC RESONANCE IN MEDICINE, 1990, 14 (02) :415-422
[18]  
NELSON SJ, 1990, 9TH P SMRM ANN M NEW, P1059
[19]   CHEMICAL-SHIFT IMAGING OF HUMAN BRAIN - AXIAL, SAGITTAL, AND CORONAL P-31 METABOLITE IMAGES [J].
VIGNERON, DB ;
NELSON, SJ ;
MURPHYBOESCH, J ;
KELLEY, DAC ;
KESSLER, HB ;
BROWN, TR ;
TAYLOR, JS .
RADIOLOGY, 1990, 177 (03) :643-649
[20]   ERRORS OF FOURIER CHEMICAL-SHIFT IMAGING AND THEIR CORRECTIONS [J].
WANG, Z ;
BOLINGER, L ;
SUBRAMANIAN, VH ;
LEIGH, JS .
JOURNAL OF MAGNETIC RESONANCE, 1991, 92 (01) :64-72