Artificial electrical stimulation of peripheral nerves needs the development of multielectrode devices which stimulate individual fibers or small groups in a selective and sensitive way. To this end, a multielectrode array in silicon technology has been developed, as well as experimental paradigms and model calculations for sensitivity and selectivity measures. The array consists of twelve platinum electrode sites (10 x 50-mu-m at 50-mu-m interdistance) on a 45-mu-m thick tip-shaped silicon substrate and a Si3N4 insulating glass cover layer. The tip is inserted in the peroneal nerve of the rat during acute experiments to stimulate alpha motor fibers of the extensor digitorum longus muscle. Sensitivity calculations and experiments show a cubic dependence of the number of stimulated motor units on current amplitude of the stimulatory pulse (recruitment curves), starting at single motor level. Selectivity was tested by a method based on the refractory properties of neurons. At the lowest stimulus levels (for one motor unit) selectivity is maximal when two electrodes are separated by 200-250-mu-m, which was estimated also on theoretical grounds. The study provides clues for future designs of two- and three-dimensional devices.
引用
收藏
页码:192 / 198
页数:7
相关论文
共 24 条
[11]   A SPIRAL NERVE CUFF ELECTRODE FOR PERIPHERAL-NERVE STIMULATION [J].
NAPLES, GG ;
MORTIMER, JT ;
SCHEINER, A ;
SWEENEY, JD .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1988, 35 (11) :905-916
[12]  
OLSON WH, 1973, THESIS U MICHIGAN AN
[13]   SILICON AS A MECHANICAL MATERIAL [J].
PETERSEN, KE .
PROCEEDINGS OF THE IEEE, 1982, 70 (05) :420-457
[14]   THIN-FILM MULTIPLE ELECTRODE PROBES - POSSIBILITIES AND LIMITATIONS [J].
PROHASKA, OJ ;
OLCAYTUG, F ;
PFUNDNER, P ;
DRAGAUN, H .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1986, 33 (02) :223-229
[15]   WHICH ELEMENTS ARE EXCITED IN ELECTRICAL-STIMULATION OF MAMMALIAN CENTRAL NERVOUS-SYSTEM - REVIEW [J].
RANCK, JB .
BRAIN RESEARCH, 1975, 98 (03) :417-440
[17]   ACTIVATED IR - AN ELECTRODE SUITABLE FOR REVERSIBLE CHARGE INJECTION IN SALINE SOLUTION [J].
ROBBLEE, LS ;
LEFKO, JL ;
BRUMMER, SB .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1983, 130 (03) :731-733
[18]  
RUTTEN WLC, 1988, INT CONGR SER, V804, P135
[19]   EXTERNAL CONTROL OF THE NEUROMUSCULAR SYSTEM [J].
SOLOMONOW, M .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1984, 31 (12) :752-763
[20]   MOTONEURONS OF THE RAT SCIATIC-NERVE [J].
SWETT, JE ;
WIKHOLM, RP ;
BLANKS, RHI ;
SWETT, AL ;
CONLEY, LC .
EXPERIMENTAL NEUROLOGY, 1986, 93 (01) :227-252