PAST, PRESENT AND FUTURE CONTRIBUTIONS OF MICROELECTRODES TO ANALYTICAL STUDIES EMPLOYING VOLTAMMETRIC DETECTION - A REVIEW

被引:163
作者
BOND, AM
机构
关键词
MICROELECTRODE; VOLTAMMETRY IN ELECTROCHEMICALLY EXOTIC MEDIA; ADVANTAGES AND DISADVANTAGES OF MICROELECTRODES;
D O I
10.1039/an994190001r
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Traditionally, electroanalytical studies employing voltammetric techniques with conventionally sized solid electrodes (e.g., 1-5 mm radius disc) hare been applied in a relatively small range of conducting solvent (electrolyte) media under transient (time-dependent) conditions. In this review it is emphasized that many of the limitations associated with the use of conventional voltammetric electrodes have either been removed or greatly minimized via the use of microelectrodes (e.g., less than or equal to 25 mu m radius disc). A major feature of microelectrode voltammetry is the ready access to near steady-state conditions (radial diffusion) where the influence of the ohmic (iR) drop is considerably reduced relative to that associated with the transient response (linear diffusion). Additionally, under near steady-state conditions, electrochemically derived charging current terms are negligible. Consequently, provided that the difficulties in fabricating and maintaining microelectrodes with high quality seals and electrical contacts can be overcome, then close to the analytically ideal response may be achieved with simple two-electrode (microelectrode and reference electrode) instrumental configurations and applied d.c. waveforms. The need for more complicated potentiostatic forms of instrumentation and relatively sophisticated pulse, square-wave or alternating current techniques is, therefore, reduced. In order to emphasize the wide range of electrochemically exotic media that are now voltammetrically accessible via the use of microelectrodes, representative studies without deliberately added electrolyte (dilute electrolyte), in high resistance organic solvents such as toluene and heptane, in supercritical fluids, at very low temperatures and in the gaseous and solid-state phases are reviewed. Additionally, the very small physical size of a microelectrode sensing element enables their use in precise locations as is often required when monitoring biologically important molecules in single cells or in situations where high spatial resolution is required. Other advantages related to the small physical size of microelectrodes are also reviewed, although it is noted that the determination of oxygen in muscle tissue with a microelectrode was first reported more than 50 years ago, so that in one sense microelectrode voltammetry is not fundamentally new. The review concludes with a discussion of the advantages and disadvantages of microelectrode voltammetry.
引用
收藏
页码:R1 / R21
页数:21
相关论文
共 156 条
[51]   ELECTROCHEMISTRY IN NEAR-CRITICAL AND SUPERCRITICAL FLUIDS .6. THE ELECTROCHEMISTRY OF FERROCENE AND PHENAZINE IN ACETONITRILE BETWEEN 25-DEGREES-C AND 300-DEGREES-C [J].
CROOKS, RM ;
BARD, AJ .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1988, 243 (01) :117-131
[52]   Microelectrodes for measuring local oxygen tension in animal tissues [J].
Davies, PW ;
Brink, F .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1942, 13 (12) :524-533
[53]  
DEVITRE RR, 1991, ANAL P, V28, P74
[54]   APPLICATION OF NAFION PLATINUM-ELECTRODES (SOLID POLYMER ELECTROLYTE STRUCTURES) TO VOLTAMMETRIC INVESTIGATIONS OF HIGHLY RESISTIVE SOLUTIONS [J].
DEWULF, DW ;
BARD, AJ .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1988, 135 (08) :1977-1985
[55]   PROGRESS IN SENSOR ARRAY RESEARCH [J].
DIAMOND, D .
ELECTROANALYSIS, 1993, 5 (9-10) :795-802
[56]   ELECTRO-ORGANIC SYNTHESIS IN SUPERCRITICAL ORGANIC MIXTURES [J].
DOMBRO, RA ;
PRENTICE, GA ;
MCHUGH, MA .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1988, 135 (09) :2219-2223
[57]   MEASUREMENTS WITHIN THE DIFFUSION LAYER USING A MICROELECTRODE PROBE [J].
ENGSTROM, RC ;
WEBER, M ;
WUNDER, DJ ;
BURGESS, R ;
WINQUIST, S .
ANALYTICAL CHEMISTRY, 1986, 58 (04) :844-848
[58]   ELECTROCHEMICAL DETECTION IN MICROCOLUMN SEPARATIONS [J].
EWING, AG ;
MESAROS, JM ;
GAVIN, PF .
ANALYTICAL CHEMISTRY, 1994, 66 (09) :A527-A537
[59]   HEAVY-METAL DETERMINATION AND SPECIATION - ANODIC-STRIPPING VOLTAMMETRY EMPLOYING MICROELECTRODES [J].
FEINBERG, JS ;
BOWYER, WJ .
MICROCHEMICAL JOURNAL, 1993, 47 (1-2) :72-78
[60]   ELECTROCHEMISTRY IN NEAR-CRITICAL AND SUPERCRITICAL FLUIDS .3. STUDIES OF BR-, I-, AND HYDROQUINONE IN AQUEOUS-SOLUTIONS [J].
FLARSHEIM, WM ;
TSOU, YM ;
TRACHTENBERG, I ;
JOHNSTON, KP ;
BARD, AJ .
JOURNAL OF PHYSICAL CHEMISTRY, 1986, 90 (16) :3857-3862