DETERMINATION OF ORGANIC-ACIDS, AMINO-ACIDS AND SACCHARIDES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND A POSTCOLUMN ENZYME REACTOR WITH AMPEROMETRIC DETECTION

被引:16
作者
MOGELE, R [1 ]
PABEL, B [1 ]
GALENSA, R [1 ]
机构
[1] TECH UNIV BRAUNSCHWEIG,INST FOOD CHEM,SCHLEINITZSTR 20,W-3300 BRAUNSCHWEIG,GERMANY
来源
JOURNAL OF CHROMATOGRAPHY | 1992年 / 591卷 / 1-2期
关键词
D O I
10.1016/0021-9673(92)80234-L
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A technique for the determination of organic acids, amino acids and sugars is described. The compounds of interest are separated by high-performance liquid chromatography (HPLC) and converted on-line by immobilized enzymes. The enzymes employed are covalently bound to a synthetic carrier. Hydrogen peroxide, which is produced in the reaction with oxidases, makes possible the application of an electrochemical detector. This arrangement combines the separation efficiency of HPLC, the substrate specificity of enzymes and the high sensitivity of electrochemical detection. The enzymes act according to known reaction mechanisms, but coupling with HPLC leads to a promising extension in the field of biosensors. The simple pretreatment of the samples (often a dilution step is sufficient) allows a rapid analysis of foodstuffs and biological or clinical extracts. The examples presented demonstrate the very high sensitivity of the method with detection limits in the nano- to picomolar range and a wide field of application.
引用
收藏
页码:165 / 173
页数:9
相关论文
共 51 条
[21]   DESIGN OF ENZYME REACTORS AS CHROMATOGRAPHIC COLUMNS FOR RACEMIC-RESOLUTION OF AMINO-ACID ESTERS [J].
KALBE, J ;
HOCKER, H ;
BERNDT, H .
CHROMATOGRAPHIA, 1989, 28 (3-4) :193-196
[22]   ANION-EXCHANGE SEPARATION OF CARBOHYDRATES WITH PULSED AMPEROMETRIC DETECTION USING A PH-SELECTIVE REFERENCE ELECTRODE [J].
LACOURSE, WR ;
MEAD, DA ;
JOHNSON, DC .
ANALYTICAL CHEMISTRY, 1990, 62 (02) :220-224
[23]  
LEMIEUX L, 1989, LEBENSM WISS TECHNOL, V22, P254
[25]   DETERMINATION OF SACCHARIDES BY HIGH-PERFORMANCE ANION-EXCHANGE CHROMATOGRAPHY WITH PULSED AMPEROMETRIC DETECTION [J].
MARTENS, DA ;
FRANKENBERGER, WT .
CHROMATOGRAPHIA, 1990, 29 (1-2) :7-12
[26]   IN-LINE DETERMINATION OF METABOLITES AND MILK COMPONENTS WITH ELECTROCHEMICAL BIOSENSORS [J].
MASCINI, M ;
MOSCONE, D ;
PALLESCHI, G ;
PILLOTON, R .
ANALYTICA CHIMICA ACTA, 1988, 213 (1-2) :101-111
[27]   SIMULTANEOUS DETERMINATION OF GLUCOSE, FRUCTOSE, AND SUCROSE IN MIXTURES BY AMPEROMETRIC FLOW-INJECTION ANALYSIS WITH IMMOBILIZED ENZYME REACTORS [J].
MATSUMOTO, K ;
KAMIKADO, H ;
MATSUBARA, H ;
OSAJIMA, Y .
ANALYTICAL CHEMISTRY, 1988, 60 (02) :147-151
[28]   SIMULTANEOUS DETERMINATION OF GLUCOSE, ETHANOL AND LACTATE IN ALCOHOLIC BEVERAGES AND SERUM BY AMPEROMETRIC FLOW-INJECTION ANALYSIS WITH IMMOBILIZED ENZYME REACTORS [J].
MATSUMOTO, K ;
MATSUBARA, H ;
HAMADA, M ;
UKEDA, H ;
OSAJIMA, Y .
JOURNAL OF BIOTECHNOLOGY, 1990, 14 (01) :115-126
[29]  
MATSUMOTO K, 1990, IN PRESS GBF BIOSENS
[30]   ENZYMES ADSORBED ON AN ION-EXCHANGER AS A POST-COLUMN REACTOR - APPLICATION TO ACETYLCHOLINE MEASUREMENT [J].
MEEK, JL ;
EVA, C .
JOURNAL OF CHROMATOGRAPHY, 1984, 317 (DEC) :343-347